background image

 

 

                                                                                   CenterLine 230BP; Müller SPRAYDOS Installation Manual 

  

 

 

 

                                                                                                                     020-041-UK R5

5

 

 

                                                                                   CenterLine 230BP; Müller SPRAYDOS Installation Manual 

  

 

 

 

                                                                                                                     020-041-UK R5

CenterLine 230BP; Müller SPRAYDOS Installation Manual    

 

 

                                                                                                                     

020-041-UK R5

1008-0190

SYSTEM DESCRIPTION:

POS DESCRIPTION

1

CenterLine 230BP

2

Speed output connector

3

RS232 port (Programming and GPS input)

4

Fuse 3A

5

Foot switch connector 2P (Foot switch is optional)

6

CAN connector 4P

7

Power connector 2P

8

BoomPilot adapter cable (PN 199-263)

9

Müller SPRAYDOS adapter cable, (! Different part number for 5, 7 and 9 section)

10

ABSC adapter box, PN 902-361

11

Power connector, ABSC adapter box

12

SPRAYDOS controller

13

Machine connector from ABSC box

14

Power connector, Müller SPRAYDOS 

15

Machine connector from Sprayer

INSTALLING THE SPRAYDOS ADAPTER CABLE

To get electrical contact with the sections and the Master switch in the SPRAYDOS, it's necessary 

to install the adapter cable (POS. 9), in the SPRAYDOS controller. This is a critical operation and 

must only be conducted of persons with the necessary skills.

SPRAYDOS adapter cable

The  adapter  cable  can  only  be  installed 
in  SPRAYDOS  controllers  where  the  con-
nector  between  the  processor  board  and 
the  main  board  is  a  'Low-profile'  type 
(See picture 'OLD TYPE').
In case the SPRAYDOS controller is dam-
aged  during  the  installation,  it's  on  the 
buyers sole risk and therefore the buyer is 
not entitled to any form for compensation.

 

Содержание Centerline 230BP

Страница 1: ...020 041 UK R5 Installation Manual for M ller SPRAYDOS controller...

Страница 2: ...any of the following Disturbance to from any electronic services or products that do not confirm to the standards for CE marking Missing or poor signal coverage or a succession hereof from exter nal...

Страница 3: ...lves in automatic mode and the controller section switches should be set to off unless the operator wants to override the auto mode and thus force spraying The Centerline 230BP monitors the controller...

Страница 4: ...DOS Installation Manual 020 041 UK R5 4 CenterLine 230BP M ller SPRAYDOS Installation Manual 020 041 UK R5 AUT MATIC B OM SECTION CONTROL 1008 0185 B A B A A B SYSTEM OVERVIEW Note CenterLine 230 is p...

Страница 5: ...x 14 Power connector M ller SPRAYDOS 15 Machine connector from Sprayer INSTALLING THE SPRAYDOS ADAPTER CABLE To get electrical contact with the sections and the Master switch in the SPRAYDOS it s nece...

Страница 6: ...om of the profile Be care full the wires are just long enough to make it possible to un screw the buzzer from the profile Not all SPRAYDOS controllers has the buzzer fastened as shown some has it plac...

Страница 7: ...in the bottom plastic end plate between the power cable gland and the rear edge of the end plate Make a 1 5 mm gab as shown on the picture Place the free wires of the SPRAYDOS adapt er cable one by on...

Страница 8: ...4 8 7 Connect the small adapter circuit board to the keypad flat cable connector as shown on the picture Place the protection plastic plate B with the adhesive tape as shown on the picture To protect...

Страница 9: ...K R5 10 11 12 Connect the small adapter circuit board to the controller board Make sure the connectors are correct positioned and fully connected Place the adapter cable wires inside the con troller P...

Страница 10: ...ct the system as shown in the system overview draw ing CONNECTING POS 11 14 TO POWER POS DESCRIPTION 1 12V 15 30 2 Ground 31 The power supply must be strong enough to operate the Sec tion and Master v...

Страница 11: ...mber of sections and the width of each Refer to the CL230 user manual Wait for DGPS Green LED on Set the mode to AUTO Drive forward Min Speed 2 3 km h Observe that all sections and the master valve op...