from the return safety valve into the drain, you can avoid the dripping by installing a 3-litre 

expansion tank on the inlet water pipe of the boiler.
Water may come out in drops from the exhaust pipe of pressure reduction device i.e, safety 

valve, this pipe has to be open and positioned downwise, to prevent freezing of the water in 
the pipe. By regular function of the safety valve it should be possible to remove
limescale sediment as well as to check if it is bloacked. Safety valve is delivered with the 
water heater and the sheme shows how to install it. At installation of a water heater and its 
connection to water supply, it is recomanded to use new set of hoses, old ones should not 
be used. 
CONNECTION TO POVER SUPPLY
Electric accumulation water heater is connected to power supply by valid standards for 

electrical installations, with a plug cable 3x1,5 mm H05VV.

Before connecting power supply cable, unscrew the two screws and remove protection cap 
of the electric water heater. The electric water heater is not delivered with a device to cut off 
the power from the supply permanently. A separating element of all the poles from the supply 
should be included, according to local installation rules. Such separating means have to be 
included in the electrical installation.

1. Thermoregulator

2. Heater

3. Connection clamp

4. Signal lamp

L – phase

N neutral

Ground  

WARNING

: Before any intervention the water heater must be disconnected

from the power supply line.

USE, CONTROL, MAINTENANCE OF ELECTRIC WATER HEATERS

After connecting it to water and power supplies the water heater is ready to use. For types 

without external heater regulation (no button on the cover), water temperature is regulated 

by a preset thermoregulator. It is recomanded not to change the set temperature (t=55°C)
being optimal for saving energy and minimum limestone sedimentation. Should the user 

however want to change the temperature of water heating, the water heater should first be 

disconnected from power supply line, protection cap on the bottom should be taken off, and 
by turning plastic button directly on the thermoregulator, water heating temperature can be 
set to be lower or higher within the range 20 to 70±5°C.

Содержание PRAKTIK MB 100

Страница 1: ...AND CARE OF WATER HEATERS STANDARD MB 30 50 80 lit STANDARD MB 80 H PRAKTIK MB 50 80 100 120 lit PRAKTIK MB 50 80 100 120 lit Inox PRAKTIK MB PK 80 120 lit PRAKTIK MB PK 80 120 lit Inox SLIM MB 30 50...

Страница 2: ...2 EN CONTENTS Technical information 3 Installation 4 Connection to water supply 8 Connection to power supply 9 Use control and maintenace of electrical water heaters 10 Waste disposal 11...

Страница 3: ...ers are designed to work with pressure of the water supply pipeline The appliance is not meant for persons including children of reduced psychophysical abilities unless under supervision of persons re...

Страница 4: ...0 80 Weight when full of water kg 0 6 0 6 0 6 Weight when full of water kg 17 47 22 72 29 109 Corrosion protection type Enamelled Mg anode Enamelled Mg anode Enamelled Mg anode Heater power W 2000 200...

Страница 5: ...6 Weight when full of water kg 29 109 Corrosion protection type Enamelled Mg anode Heater power W 2000 Voltage 230 Time of water heating from 15 C to 75 C 320 The tank is insulated with quality polyur...

Страница 6: ...3 395 454 354 300 130 360 320 130 360 130 240 300 793 744 603 395 454 354 600 130 360 460 130 360 380 240 300 KLASSA MB 50 SG KLASSA MB 80 KLASSA MB 80 SG KLASSA MB 50 604 860 219 219 480 110 480 110...

Страница 7: ...415 610 Left water heater MB 80 HL Right water heater MB 80 HD Horisontal water heaters could be mounted as left or right depending on the position of the thermoregulator and this models are designed...

Страница 8: ...water An interlocking must not come between the safety valve and the water heater as it would disable safety valve function Fill the water heater with water before connecting it to electric power sup...

Страница 9: ...ctric water heater is not delivered with a device to cut off the power from the supply permanently A separating element of all the poles from the supply should be included according to local installat...

Страница 10: ...uld be removed regularly For such interventions tank must be emptied To empty the tank please proceed as follows Disconnect the water heater from power supply Close the inlet cold water valve Open the...

Страница 11: ...1592 50 0700 19889 e mail office tedanbg com Premium quality...

Отзывы: