For water heater types with external regulation, by simple turning the button desired 

water heating temperature can be set within the range 20 to 70±5°C. When desired/ set 
temperature is reached inside the the tank the thermoregulator will cut the power circuit 
automatically, and the signal lamp which has been on during the heating time,
will go off. 

WARNING

: before using hot water from water heater turn it off from elecrical power 

supply.

Water heaters also have thermometers with metal cap and bimetal showing the temperature 
of the water. If water heater will not be used for longer period it is recomanded to disconnect 
it from power supply line. If water inside the water heater could freeze while not used it 
is recomanded to empty the tank. The miantenance tips should be respected, especially 
check-up for how much Mg anode is consumed, at least every 36 months, and replace it if 
needed. The limestone sediment should be removed regularly.
For such interventions tank must be emptied.
To empty the tank please proceed as follows:
- Disconnect the water heater from power supply
- Close the inlet cold water valve
- Open the hot water pipe
- Unscrew the safety valve mounted on the cold water inlet, and wait
for water to go out.

After that the unscrew the nut of the heater counterflange, take out the flange with the heater, 

remove the limescale and replace Mganode. If you use chemical products for limescale 
removal, they must not come into contact with Mg-anode (anode should be taken out). 

Afterwards the tank should be rinsed and refilled with water.

WASTE DISPOSAL – WHAT AFTER YOUR WATER HEATER IS

NO MORE USABLE

The accumulation water heaters and the packing are made of recyclable 

materials. After your water heater is not usable any more, it is forbidden 

to dispose it as non-selected waste. For waste disposal, the water heater 

plactic and rubber parts should be separated from metal parts, classified 

and left for recycling or

final disposal according to loacal regulations.Only by waste separation and 

management you will protect the environment.

Содержание PRAKTIK MB 100

Страница 1: ...AND CARE OF WATER HEATERS STANDARD MB 30 50 80 lit STANDARD MB 80 H PRAKTIK MB 50 80 100 120 lit PRAKTIK MB 50 80 100 120 lit Inox PRAKTIK MB PK 80 120 lit PRAKTIK MB PK 80 120 lit Inox SLIM MB 30 50...

Страница 2: ...2 EN CONTENTS Technical information 3 Installation 4 Connection to water supply 8 Connection to power supply 9 Use control and maintenace of electrical water heaters 10 Waste disposal 11...

Страница 3: ...ers are designed to work with pressure of the water supply pipeline The appliance is not meant for persons including children of reduced psychophysical abilities unless under supervision of persons re...

Страница 4: ...0 80 Weight when full of water kg 0 6 0 6 0 6 Weight when full of water kg 17 47 22 72 29 109 Corrosion protection type Enamelled Mg anode Enamelled Mg anode Enamelled Mg anode Heater power W 2000 200...

Страница 5: ...6 Weight when full of water kg 29 109 Corrosion protection type Enamelled Mg anode Heater power W 2000 Voltage 230 Time of water heating from 15 C to 75 C 320 The tank is insulated with quality polyur...

Страница 6: ...3 395 454 354 300 130 360 320 130 360 130 240 300 793 744 603 395 454 354 600 130 360 460 130 360 380 240 300 KLASSA MB 50 SG KLASSA MB 80 KLASSA MB 80 SG KLASSA MB 50 604 860 219 219 480 110 480 110...

Страница 7: ...415 610 Left water heater MB 80 HL Right water heater MB 80 HD Horisontal water heaters could be mounted as left or right depending on the position of the thermoregulator and this models are designed...

Страница 8: ...water An interlocking must not come between the safety valve and the water heater as it would disable safety valve function Fill the water heater with water before connecting it to electric power sup...

Страница 9: ...ctric water heater is not delivered with a device to cut off the power from the supply permanently A separating element of all the poles from the supply should be included according to local installat...

Страница 10: ...uld be removed regularly For such interventions tank must be emptied To empty the tank please proceed as follows Disconnect the water heater from power supply Close the inlet cold water valve Open the...

Страница 11: ...1592 50 0700 19889 e mail office tedanbg com Premium quality...

Отзывы: