background image

P. 7

 | Tecshow Navigator Split RDM

English version

6. MAINTENANCE

The Navigator Split RDM requires almost no main-

tenance. However, you should keep the unit clean. 

Disconnect the mains power supply, and then wipe 

the cover with a damp cloth. Do not immerse in 

liquid. Do not use alcohol or solvents. Keep connec-

tions clean. Disconnect electric power, and then 

wipe the DMX/RDM connections with a damp cloth. 

Make sure connections are thoroughly dry before 

linking equipment or supplying electric power.

Replacing the Fuse 

Power surges, short-circuit or inappropriate elec-

trical power supply may cause a fuse to burn out. 

If the fuse burns out, the product will not function 

Fixture Linking

You will need a serial data link to run light shows 

of one or more fixtures using a DMX-512 control

-

ler or to run synchronized shows of two or more 

fixtures set to a master/slave operating mode. The 

combined number of channels required by all the 

fixtures on a serial data link determines the number 

of fixtures the data link can support.

Important: 

Fixtures on a serial data link must be 

daisy-chained in a single line. To comply with the 

EIA485 standard, no more than 30 devices should 

be connected on one datalink. Connecting more 

than 30 fixtures on one serial data link without the 

what so ever. If this happens, follow the directions 

below. 

1) Unplug the unit from electric power source. 

2) Insert a screwdriver into the fuse holder. Turn the 

fuse holder counter clockwise. The fuse holder will 

come out. 

3) Remove the used fuse. If brown or unclear, it is 

burned out. 

4) Insert the replacement fuse into the holder 

where the old fuse was. Reinsert the fuse holder. Be 

sure to use a fuse of the same type and specifica

-

tion. See the product specification label for details.

use of a DMX optically isolated splitter may result 

in deterioration of the digital DMX signal. Maximum 

recommended DMX data link distance: 100 meters 

Maximum recommended number of fixtures on a 

DMX data link: 30 fixtures.

Data Cabling 

To link fixtures together you must obtain data ca

-

bles. If you choose to create your own cable please 

use data grade cables that can carry a high quality 

signal and are less prone to electromagnetic inter-

ference.

Содержание NAVIGATOR SPLIT RDM

Страница 1: ...cshow Navigator Split RDM NAVIGATOR SPLIT RDM DMX RDM Splitter 2 inputs 4 outputs USER MANUAL MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCIÓNES ANTES DE USAR ...

Страница 2: ... to show its status at a glance Navigator Split RDM is an ideal solution for for those who want a reliable yet versatile splitter with RDM function Specifications Features DMX splitter booster RDM capable bidirectional 19 inch rack mountable 4 outputs with 3 5 pin connectors Optically isolated Support DMX upgrade Technical DMX ANSI E1 11 RDM ANSI E1 20 Power input connector 1 PowerCon connector Ph...

Страница 3: ...r cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never look directly into the light source Never leave any cables lying around Never use the device during thunder storms unplug the device immediately Never leave various p...

Страница 4: ... return it to your dealer for service For adult use only The device must be installed out of the reach of children Never leave the unit running unattended For replacement use fuses of same type and ratingonly The user is responsible for correct positioning and operating of the RDM Splitter The manu facturer will not accept liability for damages caused by the misuse or incorrect installation of thi...

Страница 5: ...DMX LED indicator 3 3 pin DMX signal connector IN 4 3 pin DMX signal connector THROUGH 8 Power switch ON OFF 9 Pro power connector IN 10 Fuse 1A 250V 5 5 pin DMX signal connector IN 6 5 pin DMX signal connector THROUGH 7 3 5 pin DMX signal connectors OUT 11 Ground earth connection 12 M10 clamp thread 13 Terminal resistor ...

Страница 6: ...0V specification product on 230V power or vice versa Connect the device to the main power supply Control Modes Multiple RDM Splitters DMX control 1 Fasten the distributor to a 19 inch rack 2 Use a 3 pin 5 pin XLR cable to connect the Navi gator Split RDM and other devices 3 Connect the first unit s in socket to a light controller 4 Link the units as shown in figure Connect the first unit s DMX lin...

Страница 7: ...he data link can support Important Fixtures on a serial data link must be daisy chained in a single line To comply with the EIA485 standard no more than 30 devices should be connected on one datalink Connecting more than 30 fixtures on one serial data link without the what so ever If this happens follow the directions below 1 Unplug the unit from electric power source 2 Insert a screwdriver into t...

Страница 8: ... control again 3 Determine whether the distributor controller or light effect is at fault If the distributor or controller does not operate properly take the distributor or controller in for repair Otherwise take the DMX cable and the light effect to a qualified technician Problem Probable cause s Solution One or more fixtures do not function at all No power to the fixture Check if power is switch...

Страница 9: ...technician 3 pin 5 pin XLR Out on the fix tures does not match pins 2 and 3 reversed Install a phase reversing cable between the fixtures or swap pin 2 and 3 in the fixture that behaves erratically No light or LEDs lamp cuts out intermittently Fixture is too hot Allow the fixture to cooldown Clean the fan Make sure air vents in control panel and the front lens are not blocked Turn up the air condi...

Страница 10: ...e permite ver su status facil mente Navigator Split RDM es una solución ideal para aquellos que buscan un splitter confiable que incluya funcionalidad RDM y cuente con conectores de 3 y 5 pines Especificaciones Características Splitter DMX RDM compatible bidireccional Rackeable de 19 pulgadas 4 salidas con conectores XLR de 3 y 5 pines Señales ópticamente aisladas Soporta actualización DMX Técnica...

Страница 11: ...en contacto con un profesional idóneo Importante No permita que el cable de suministro eléctrico entre en contacto con otros cables Utilice el cable y todas las conexiones con extrema pre caución No retire las etiquetas informativas o de adver tencia de la unidad No obstruya ni elimine el contacto a tierra de la unidad Nunca mire en forma directa a la salida de luz No deje cables sueltos en las in...

Страница 12: ...ga do hasta que alcance la temperatura ambiente Desconecte el equipo de inmediato si obser va un funcionamiento anómalo Coloque la unidad en su embalaje original y llévelo a su distribuidor para que lo revise Este equipo solo puede ser operado por adul tos Mantenga la unidad alejada del alcance de los niños No deje la unidad en funcionamiento y sin supervisión Utilice repuestos originales y del mi...

Страница 13: ...Indicador LED DMX 3 Conector de entrada DMX XLR 3 4 Conector thru DMX XLR 3 8 Interruptor de encendido apagado 9 Conector de entrada Pro power 10 Fusible 1A 250 V 5 Conector de entrada DMX XLR 5 6 Conector thru DMX XLR 5 7 Conector de salida DMX XLR 3 y XLR 5 11 Conexión a tierra 12 Orificio M10 para abrazadera 13 Resistencia terminal ...

Страница 14: ... indicado en la presente guía Nunca conecte un equipo de 120 V a una red de 230 V o viceversa Una vez realizados los pasos anteriores conecte el equipo al suministro eléctrico Modos de control Varios splitters RDM DMX 1 Coloque la unidad en un bastidor estándar de 19 nistro eléctrico antes de realizar cualquier tarea de mantenimiento pulgadas 2 Conecte un cable XLR 3 o XLR 5 para enlazar los Navig...

Страница 15: ...tar shows sincronizados en dos o más equipos enlazados en modo maestro esclavo El número total de canales requeridos por todas las unidades enlazadas determina el número de uni dades que el enlace de datos puede sostener queme el fusible Para reemplazarlo siga los pasos a continuación 1 Desconecte la unidad del suministro eléctrico 2 Coloque un destornillador plano en una de las ranuras de la cubi...

Страница 16: ...luego vuelva a conectar la unidad Intente utilizar el control DMX nuevamente 3 Determine si el controlador o el efecto de luz tie nen fallas Si no funcionan correctamente lleve el controlador DMX al servicio técnico De lo contrario lleve el cable DMX y el efecto de luz a un técnico autorizado Problema Causas posibles Solución Una o más unidades no funcionan La unidad no recibe alimentación Verifiq...

Страница 17: ... 2 y 3 invertidas Coloque un cable de fase inverti da entre los equipos o intercambie las clavijas 2 y 3 en el equipo que funciona erráticamente No hay salida de luz o la lámpara se apaga de forma intermitente Protección térmica Limpie el ventilador Compruebe que no estén obstru idas las ranuras de ventilación Encienda el aire acondicionado Lámpara LEDs dañados Desconecte el equipo y devuélvalo al...

Страница 18: ...P 18 Tecshow Navigator Split RDM FOR MORE INFO ON THIS PRODUCT PLEASE CHECK WWW TEC SHOW COM PARA MAS INFORMACION SOBRE ESTE PRODUCTO VISITE WWW TEC SHOW COM ...

Отзывы: