1. Wiring for 4781 & 4782
Applicable Cable Types:
Cable Type:
4781.XXXX
According to IEC60245-8
Type 60245 IEC 89
4782.XXXX
According to IEC60227-5 or IEC60245-8
Type 60227 IEC 53 or Type 60245 IEC 89
SVT (10A/125V)
SJT (15A/250V)
Max. Cable Diameter:
Ø 8.5mm for 478X.0000
Ø 10.0mm for 478X.0100
Max. Wire Size:
3x1.5mm
2
for 10A
3x16AWG
for 15A
Min. Wire Size:
3x0.75mm
2
for 10A
3x18AWG
for 15A
if cord has a length exeeding 2m, nominal cross-
sectional areas shall be 1.0mm
2
/16AWG
Torque Value
0.30Nm
Torque Value
0.30Nm
Tension Relief
30
30
9
9
35
9
Cable Clamp
IN
OUT
L
L’
PE
PE’
N
N’
N
blue
L
brown
Yellow /
green
Torque Value
0.5Nm
Cable end sleeves
(Optional, not enclosed)
1. Wiring for 4781 & 4782
Applicable Cable Types:
Cable Type:
4781.XXXX
According to IEC60245-8
Type 60245 IEC 89
4782.XXXX
According to IEC60227-5 or IEC60245-8
Type 60227 IEC 53 or Type 60245 IEC 89
SVT (10A/125V)
SJT (15A/250V)
Max. Cable Diameter:
Ø 8.5mm for 478X.0000
Ø 10.0mm for 478X.0100
Max. Wire Size:
3x1.5mm
2
for 10A
3x16AWG
for 15A
Min. Wire Size:
3x0.75mm
2
for 10A
3x18AWG
for 15A
if cord has a length exeeding 2m, nominal cross-
sectional areas shall be 1.0mm
2
/16AWG
Torque Value
0.30Nm
Torque Value
0.30Nm
Tension Relief
30
30
9
9
35
9
Cable Clamp
IN
OUT
L
L’
PE
PE’
N
N’
N
blue
L
brown
Yellow /
green
Torque Value
0.5Nm
Cable end sleeves
(Optional, not enclosed)
owner
hotzar
creation date
2016-11-08
release date
2016-11-18
released by
hotzar
change order no
2011424
rev
C
page
1 of 3
0115.0054
Engineering Documentation
Wiring for 478X