background image

1. Wiring for 4781 & 4782 

 

 
 
 
 

Applicable Cable Types:

Cable Type:

4781.XXXX

According to IEC60245-8
Type 60245 IEC 89

4782.XXXX

According to IEC60227-5 or IEC60245-8
Type 60227 IEC 53 or Type 60245 IEC 89

SVT (10A/125V)
SJT (15A/250V)

Max. Cable Diameter: 

Ø 8.5mm for 478X.0000
Ø 10.0mm for 478X.0100

Max. Wire Size:

3x1.5mm

2

for 10A

3x16AWG

for 15A

Min. Wire Size:

3x0.75mm

2

for 10A

3x18AWG

for 15A

if cord has a length exeeding 2m, nominal cross-
sectional areas shall be 1.0mm

2

/16AWG

Torque Value 
0.30Nm

Torque Value
0.30Nm

Tension Relief

30

30

9

9

35

9

Cable Clamp

IN

OUT

L

L’

PE

PE’

N

N’

N

blue

L

brown

Yellow / 

green

Torque Value 
0.5Nm

Cable end sleeves

(Optional, not enclosed)

1. Wiring for 4781 & 4782 

 

 
 
 
 

Applicable Cable Types:

Cable Type:

4781.XXXX

According to IEC60245-8
Type 60245 IEC 89

4782.XXXX

According to IEC60227-5 or IEC60245-8
Type 60227 IEC 53 or Type 60245 IEC 89

SVT (10A/125V)
SJT (15A/250V)

Max. Cable Diameter: 

Ø 8.5mm for 478X.0000
Ø 10.0mm for 478X.0100

Max. Wire Size:

3x1.5mm

2

for 10A

3x16AWG

for 15A

Min. Wire Size:

3x0.75mm

2

for 10A

3x18AWG

for 15A

if cord has a length exeeding 2m, nominal cross-
sectional areas shall be 1.0mm

2

/16AWG

Torque Value 
0.30Nm

Torque Value
0.30Nm

Tension Relief

30

30

9

9

35

9

Cable Clamp

IN

OUT

L

L’

PE

PE’

N

N’

N

blue

L

brown

Yellow / 

green

Torque Value 
0.5Nm

Cable end sleeves

(Optional, not enclosed)

owner

hotzar

creation date

2016-11-08

release date

2016-11-18

released by

hotzar

change order no

2011424

rev

C

page

1 of 3

0115.0054

Engineering Documentation

Wiring for 478X

Отзывы: