TECOM Pro-3200 Скачать руководство пользователя страница 25

Tecom Smart Portable Vibration Diagnosis Instrument operation manual 

 

 

Page 25 

- To edit user account: check the [Select]  column; click the [Edit] button, and  the 

existing settings of the account displays for you to change.   

-  To  delete  user  account:  when  the  user  was  disconnected  check  the  [Select] 

column, click the [Delete] button to remove the account. 

 

3.

 

VB200 setup   

 

This  portable  vibration  diagnosis  instrument  supports  up  to  2  magnetic  VB-
200STU for concurrent measurement, analysis, and diagnosis; see section "RS485 
wiring" for its installation.   
 
The VB-200 series vibration gauge comes with default value of RS485 ID at 15; one 
RS485 cable may connect one VB-200 series vibration gauge only; factory default 
of  this  portable  vibration  diagnosis  instrument  may  connect  two  VB-200  series 
vibration gauge; please connect the latter to the 1st and 2nd RS485 port of AG-
300 Plus2; the 3rd and 4th RS485 ports are reserved for expansion in the future; to 
connect 3 or more VB-200 series vibration gauge you need to add RS485 device in 
the management page first.   
 
Connect  only  one  VB-200  series  vibration  gauge  in  a  RS485  port,  otherwise  the 
system  may  fail  to  identify  individual  gauge  as  each  of  them  bears  the  same 
RS485 ID value of 15; please make sure only one VB-200 series vibration gauge is 
connected to one RS485 port to prevent setup confusion.   
 
Please follow steps below to add the 3rd VB-200 series vibration gauge:   

In main menu on the left, click 

[Settings] 

[RS485]

The VB200 page displays and clicks 

[Add]

 option in it.

 

Содержание Pro-3200

Страница 1: ...1 Copyright 2018 All Rights Reserved Ver R01 D C 107 0115 Pro 3200 Smart Portable Vibration Diagnosis Instrument Operation Manual ...

Страница 2: ...7 Equipment dimension 12 8 Pro3200 portable vibration diagnosis instrument view 12 9 AG 300 Plus2 view 13 10 Power supply and cord of power bank view 14 11 VB 200STU view 15 12 Vibration gauge installation position recommended 16 13 Installation Precautions 17 14 Installation Reference 18 Equipment setup 21 1 Network setup 21 2 Account setup 23 3 VB200 setup 25 4 Wireless setup 28 4 1 The wireless...

Страница 3: ...ntil the green WLAN LED indicator lights up to proceed with WiFi connection setup for your smartphone 3 In Setup WiFi menu of your smartphone look for WiFi access point name TECOM_XXXXXX the 6 digit number XXXXXX contained in the name should be the same of the last 6 digit of MAC address shown in SN label on the side of the e Gateway AG 300 Plus2 if so the WiFi network found by your smartphone is ...

Страница 4: ...iagnosis APP on your smartphone 2 Auto log in the WiFi connected e Gateway AG 300 Plus2 without any parameter setup as shown in figure below 3 Execute vibration diagnosis operation with the help of APP wizard Note 1 Network security verification is required by remote login which may include account setup and registration please consult technical service experience and refer to advanced operation m...

Страница 5: ...eers for measuring temperature and vibration at equipment power contact E M rotary machinery and motor on the spot In addition it combines measurements made on site with interactive analysis and diagnosis of the system to provide instant helpful and effective target E M equipment health analysis which in turn not only enable easy manufacturing E M equipment management and upkeep in healthy status ...

Страница 6: ...Tecom Smart Portable Vibration Diagnosis Instrument operation manual Page 6 In situ and instant vibration diagnosis information Productivity 4 0 grade ...

Страница 7: ...to download and install on your own 6 Quick installation guide electronic file 7 Portable vibration diagnostic carrying case and belt 8 Other connection related accessories VB 200STU vibration gauge IR temperature sensor VB 200STU vibration gauge Mobile communication gateway AG 300 Plus 2 Power bank Tecom smart portable vibration diagnosis instrument Motor Compressor motor Fan mot or Generator mot...

Страница 8: ...nstrument may connect and sync up to 2 vibration gauge USB interfaced sensor type VB 200 STU 2 The smartphone may monitor up to 10 AG 300 Plus2 device at the same time 3 This portable vibration diagnosis instrument supports up to 20 users for concurrent diagnosis 4 Capacity of power bank 10050mAh 5 Fully charged power bank may support portable vibration diagnosis instrument for 12 hours without st...

Страница 9: ...bration gauge to target equipment according to its installation guidelines Once wired according to aforementioned diagram your smartphone is now ready to execute test analysis and diagnosis over target equipment with the vibration diagnosis APP follow the following diagram and steps E F for computer and the Internet connection as required E Connect AG 300 Plus2 WAN port blue and LAN port of ADSL m...

Страница 10: ...ing 1 AG 300 Plus2 E gateway AG 300 Plus2 supports up to 4 vibration gauge with RS485 USB connection as shown in figure below A B C RS485 C A AG 300 Plus2 ADSL modem The Internet e Gateway Comput er RS485 USB set 1 VB 200STU RS485 USB set 2 VB 200STU RS485 USB set 3 Reserved RS485 USB set 4 Reserved ...

Страница 11: ...nect to e gateway AG 300 Plus2 as shown inthe figure below 6 Power bank wiring This portable vibration diagnosis instrument comes with power bank power cord please connect DC Plug to DC jack of AG 300 Plus2 and USB connector to USB port in power bank as shown in figure below VB 200STU VB 200STU vibration gauge RS485 USB Magnetic vibration gauge AG 300 Plus2 Target E M equipment motor Power bank po...

Страница 12: ...6 mm height 2 VB 200STU dimension 30 5mm length x 30 5mm width x 11 5mm height 3M cable 3 Power bank dimension 90 5mm length x 59mm width x 22mm height 4 Power supply dimension 70mm length x 29mm width x 40mm height 5 Vibration diagnosis instrument dimension 320mm length x 236mm width x 76mm height 8 Pro3200 portable vibration diagnosis instrument view ...

Страница 13: ...Tecom Smart Portable Vibration Diagnosis Instrument operation manual Page 13 9 AG 300 Plus2 view ...

Страница 14: ...Tecom Smart Portable Vibration Diagnosis Instrument operation manual Page 14 10 Power supply and cord of power bank view ...

Страница 15: ...Tecom Smart Portable Vibration Diagnosis Instrument operation manual Page 15 11 VB 200STU view VB 200STU body with USB cable view ...

Страница 16: ... 3 See diagram below for recommended installation position where the arrow symbol indicates direction and letter x the installation position Vibration gauge 3 axis direction Vertical Vertical Horizontal Axial Axial Axial Vertical Vertical Axial 3 Axials X Y Z Position 3 Axials X Y Z Installation Location 安裝位置圖 Horizontal Horizontal Horizontal VB 200STU Direction identification Direction identifica...

Страница 17: ... the vibration value will increase but also increases the frequency of unpredictable In practice the vibrating gauge mounted with a magnet will be secured with quick drying glue 3 The point of installation must be thick steel such as a motor body Do not install on fan covers or heat sink fins or thin iron plates because they are too thin and easy to resonate vibration values increase and produce u...

Страница 18: ...e placed just above the rotating shaft At this time the Z axis of the vibration gauge is the vertical direction Please note that the two legs of the magnet are parallel to the rotating shaft so that they can be fixed on the arc surface of the motor on Y X Y X Z Y X Z Y X X Z X X Z X When using the vertical installation position the figure represents the measured correct X Y Z vibration axis ...

Страница 19: ...ion At this time the Z axis of the vibration gauge is the horizontal direction If you measure only one point it is recommended to use this point Vibration measurement of the vertical direction to be placed on top of the rotating shaft then the vibration of the Z axis is the vertical direction please note that the two legs of the magnet parallel to the axis of rotation it can be fixed in the motor ...

Страница 20: ...vibration At this time the Z axis of the vibration gauge is the horizontal direction If you measure only one point it is recommended to use this point Vibration measurement of the vertical direction to be placed on top of the rotating shaft then the vibration of the Z axis is the vertical direction please note that the two legs of the magnet parallel to the axis of rotation it can be fixed in the ...

Страница 21: ...nd e gateway AG 300 Plus2 in the same LAN segment better have DHCP enabled on your PC NB Connect PC NB and AG 300 Plus2 LAN port with Ethernet cable Connect power adaptor to AG 300 Plus2 Open a browser on the connection input AG 300 Plus2 setup page address http 192 168 168 10 Input user name admin Input password IP585xAdmin Click OK ...

Страница 22: ...put subnet mask data Default gateway input default gateway data Primary DNS server input main DNS server data Secondary DNS serverinput secondary DNS server Click the Apply button at bottom of page once all settings were made successfully Try connecting to popular web sites e g edition cnn com and www yahoo com tw to validate external networking function Set smartphone APP communication port to TC...

Страница 23: ...ion Diagnosis Instrument operation manual Page 23 2 Account setup Step 1 In the Main Manu section on the left click Settings Unit pairing then select the Add button Step 2 Check the Select column before selecting the Edit button ...

Страница 24: ...ion manual Page 24 Name input user name Account e g 103 you can have 20 account with number in range of 100 119 Password input password better the same as account ID Click Save button at bottom of page to keep settings you have made Click Start pairing button ...

Страница 25: ...series vibration gauge only factory default of this portable vibration diagnosis instrument may connect two VB 200 series vibration gauge please connect the latter to the 1st and 2nd RS485 port of AG 300 Plus2 the 3rd and 4th RS485 ports are reserved for expansion in the future to connect 3 or more VB 200 series vibration gauge you need to add RS485 device in the management page first Connect only...

Страница 26: ...ion manual Page 26 Name VB 200 or any name you like Line select line 3 4 line 1 2 added by factory default RS485 ID please fill in a value compliant with your RS485 configuration this system support RS485 ID in range of 0 15 Click Save button at bottom of page ...

Страница 27: ...s of VB 200 check the Select column click the Edit button and the existing settings display for you to change To delete settings of VB 200 check the Select column click the Delete button to remove the VB 200 vibration gauge To add VB 200 vibration gauge click the Add button to add new VB 200 setup ...

Страница 28: ...tup page contains options of WiFi mode Basic Advanced Security and Station list You may set WiFi mode into Wireless AP mode and Wireless client mode The wireless AP mode is an AP with gateway serving as WiFi access point The wireless client mode set the gateway as a client to connect to other WiFi AP 4 1 The wireless AP mode configuration WiFi mode setup ...

Страница 29: ...on manual Page 29 4 1 1 Basic wireless settings This option enables user to set up basic wireless communication parameters including network name and mode with WiFi function default to Enable WiFi Enable page see figure below WiFi Disable page see figure below ...

Страница 30: ...d support channel with page as shown in figure below 4 1 3 Wireless security encryption settings This option is aimed at setting up wireless security and encryption to prevent equipment access and monitoring without certification available security modes are WPASKWPA2PSK and Disable with factory default set to the latter See figure below for page of this option ...

Страница 31: ...e Vibration Diagnosis Instrument operation manual Page 31 Set up WPA algorithm pass phrase and key renewal interval once set up and saved successfully users are required to input pass phrase set up here to connect to WiFi ...

Страница 32: ...Tecom Smart Portable Vibration Diagnosis Instrument operation manual Page 32 The client end is required to log in WiFi router of e gateway AG 300 Plus2 with his her smartphone ...

Страница 33: ...able Vibration Diagnosis Instrument operation manual Page 33 4 1 4 Station list Users of this solution may monitor clients connected to AP 4 2 WiFi mode setting Select STA mode and click Apply in the WiFi mode setting ...

Страница 34: ...t this page displays information of APs saved in the gateway you may add delete and edit information of desired AP select an AP and click Open the gateway will then auto connect to the AP even after gateway restart connection to pre set AP will be established automatically Click the Add or Edit button and the AP data edit page displays ...

Страница 35: ... station profile In most cases users may change parameters of Name SSID BSSID and Security policy and leave default value of the others intact in the station profile edit page Name name of the profile SSID name of AP BSSID MAC address of AP Security policy encryption mechanism of given AP ...

Страница 36: ...Tecom Smart Portable Vibration Diagnosis Instrument operation manual Page 36 4 2 3 Station link status Link information after gateway connected to AP is shown here 4 2 4 Scan near AP ...

Страница 37: ... to scan neighboring APs once again Scanning may fail to identify all APs when there are many available nearby rescan couple of times may be needed in case like this Click the Add profile button to save AP data in station profile file 5 Hardware setup AG 300 Plus2 pins definition diagram Vibration gauge RS485 USB connection input Line 2 4 Vibration gauge RS485 USB connection input Line 1 LAN port ...

Страница 38: ...bration Diagnosis APP on your smartphone 2 This vibration diagnosis instrument provides PnP quick online diagnosis log in account 100 119 without other parameter settings as shown in figure below 3 Input Account 100 Password 100 Address 192 168 168 10 Name 100 or custom values defined earlier initial values of account password and name are set to be the same the system comes with 20 accounts 100 1...

Страница 39: ...th steps Input equipment data Vibration measurement Analysis diagnosis please follow APP wizard to get complete vibration analysis and diagnosis report 3 Report management Access and manage reports provided by the system distribute them to relevant personnel by email or communication software anywhere anytime 7 If you have checked the Remember Account option you may click the V icon on the right o...

Страница 40: ...nal network In the main menu on the left click Device Info Status Overview option to get Host ID in the System Info window TECOM Corp Ltd No 23 R D Rd II Hsinchu Science based Industrial Park Hsinchu Taiwan 300 TEL 886 3 5775141 FAX 886 3 5776855 http www tecom com tw Distributor Ver 01 2018 01 This manual may be modified when necessary because of improvement of the product modification or change ...

Отзывы: