![TECOM Challenger10 TS1016 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/tecom/challenger10-ts1016/challenger10-ts1016_installation-and-quick-programming-manual_1072566032.webp)
26
Challenger10 Installation and Quick Programming Manual
13. Program alarm groups via Install menu option 5 Alarm Groups.
14. If your system requires more than 16 inputs, or requires advanced access
control functionality, then you will need to program DGPs (data gathering
panels) into the system. Program DGPs via Install menu option 4 DGP
Database.
15. Program inputs via Install menu option 1 Input Database.
16. If your system requires more than 1 arming station, then you will need to
program RASs via Install menu option 3 RAS Database.
17. Program the system’s timers via Install menu option 6 Timers, if the default
values are not suitable (see Table 2 on page 22).
18. Program the communication options to enable the Challenger system to
report alarms to the remote monitoring station, via Install menu option 9
Communications.
19. Program the behaviour of relays via Install menu option 16 Map Relays.
20. Program (at least) the first user. See “Programming users” on page 31.
Working with multi-area systems
Challenger10 can have up to 99 areas. New or defaulted Challenger panels can
arm and disarm only areas 1 to 16. This functionality is accomplished via Area
Group 1, which contains areas 1 to 16. Area Group 1 is used in the following
Alarm Groups:
• Alarm Group 2-Master RAS or Door
• Alarm Group 3-Master Code (Installer)
• Alarm Group 11-High Level User Master
• Alarm Group 12-Low Level User Master
• Alarm Group 13-All Area User Code
The default installer user 50 (PIN 4346) is assigned Alarm Group 3, which
controls only the areas contained in Area Group 1. Alarm Group 3 cannot be
edited, but Area Group 1 can have areas added to it.
Note:
If an installer needs to program a system with more than areas 1 to 16,
then they should first modify Area Group 1 so that it contains all the required
areas.
Default installer PIN
Changing the default installer PIN
The default panel programming includes PIN 4346 for user 50. The default PIN
must be changed to keep unauthorised persons from modifying your
programming or using the system without authorisation.