MAINTENANCE

Periodic  maintenance  is  essential  for  keeping your air 
conditioner efficient.
Before  carrying  out  any  maintenance ,  disconnect the 
power supply by taking the plug out from the socket.

INDOOR UNIT

ANTIDUST FILTERS

1. Open  the  front panel following  the direction  of  the

arrow

2. Keeping the front panel raised with one hand, take out

the air filter with the other hand

3. Clean the filter with water ;  if the filter is soiled with

oil,it can be washed with warm water  (not exceeding
45

).

Leave to dry in a cool and dry place.

4. Keeping the front panel raised with one hand ,  insert

the air filter with the other hand

5. Close

The  electrostatic  and  the  deodorant filter (if installed)
cannot  be  washed  or regenerated and must be replaced 
with new filters after every 6 months.

CLEANING THE HEAT EXCHANGER

1. Open  the  front  panel  of  the  unit  and  life  it till its

greatest stroke and then unhooking it from the hinges
to make the cleaning easier.

2. Clean  the  indoor  unit  using  a  cloth  with the water

( not higher than  40

)  and  neutral soap . Never use

aggressive solvents or detergents.

3. If  the outdoor unit  is clogged ,  remove the leaves and

the waste and remove the dust with air jet or a bit of water.

END OF SEASON MAINTENANCE

1. Disconnect the automatic switch or the plug.
2. Clean and replace the filters
3. On a sunny day let the conditioner work in ventilation for some hours , so that the inside of the unit can

dry completely..

 REPLACING THE BATTERIES

When:  

How:    

N.B:  Use only new batteries. Remove the batteries from the remote controller when the conditioner is not in
          operation

WARNING ! Do  not  throw  batteries  into  common  rubbish ,  they  should  be disposed of  in the special 

containers situated in the collection points.

antidust filter

1

6

 There is no confirmation beep heard from the indoor unit. 
 The LCD doesn

t act.

 Take off  the cover at back. 
 Place the new batteries respecting the s and - .

Содержание TWS-TSO26HFFT

Страница 1: ...TECO quality Air Conditioner Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference The design and specifications a...

Страница 2: ...CONTENTS 1 3 4 5 6 9 SAFETY PRECAUTIONS NAMES OF PARTS INDOOR UNIT DISPLAY EMERGENCY FUNCTION REMOTE CONTROLLER OPERATING INSTRUCTIONS OPERATION RANGE MAINTENANCE TROUBLESHOOTING 15 16 17...

Страница 3: ...s such as hair spray lacquer or paint near the unit This may cause re or combustion Do not operate the air conditioner in places near or around combustible gases Emitted gas may collect around the uni...

Страница 4: ...k The product must be properly grounded at the time of installation or electrical shock may occur For all electrical work follow all local and national wiring standards regulations and the Installatio...

Страница 5: ...be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased No Description 13 Air outlet grille Terminal block cover 14 Gas valve 15 Liquid valv...

Страница 6: ...ccording to the model but their function is the same 4 No Led Function 1 2 3 Temperature display Error code 1 Lights up during Timer operation when the air conditioner is operational 2 Displays the ma...

Страница 7: ...operation 2 Two press of the emergency button within 3 sec two beeps will lead to the forced HEATING operation 3 To switch off the unit you just need to press the button again a single long beep 4 Aft...

Страница 8: ...re will decrease 2 on the base of setting temperature Press this button to activate deactivate the Super function which enables the unit to reach the preset temperature in the shortest time In COOL mo...

Страница 9: ...SLEEP indicator 15 TUBRO indicator 16 17 HEALTHY indicator 18 ECO indicator Meaning No Symbols CLOCK indicator 1 2 3 4 5 6 7 8 9 10 11 12 13 14 FEEL mode indicator COOLING indicator DEHUMIDIFYING indi...

Страница 10: ...ons for locating and using the remote controller holder if present The remote controller be kept in a wall mounted holder Refer to picture 2 When you insert the batteries for the first time in the rem...

Страница 11: ...ccidental contact with live pants might cause unforeseeable damage or hurt The air outlet flow is uniformly dist ributed in the room It is possible to position the direction of the air in the optimal...

Страница 12: ...ing function HEAT press the MODE button until the symbol HEAT appears on the display With the button or set a temperature higher than that of the room To optimize the function of theAir conditioner ad...

Страница 13: ...witching on could be read on the display NOTE Before proceeding with the time program the working mode with the button MODE 2 and the fan speed with the button FAN 3 Switch the conditioner off with th...

Страница 14: ...ntrol also stores the speed that was set in the previous mode of operation In FEEL mode automatic the air conditioner auto matically chooses the fan speed and the mode of operation COOLING or HEATING...

Страница 15: ...g the night In cooling or dry mode the set temperature will automatically raise by1 every 60 minutes to achieve a total rise of 2 during the first 2 hours of operation In heating mode the set temperat...

Страница 16: ...e control o measure the temperature at its current location and send this signal 7 times in 2 hours to the air conditioner to enable the air conditioner to optimize the temperature around you and ensu...

Страница 17: ...or after changing the mode during operation this is a normal self protection action you need wait for about 3 minutes The table below indicates the temperature ranges the air conditioner can be opera...

Страница 18: ...ife it till its greatest stroke and then unhooking it from the hinges to make the cleaning easier 2 Clean the indoor unit using a cloth with the water not higher than 40 and neutral soap Never use agg...

Страница 19: ...his occurs when the air in the room becomes very cold for example in the COOLING or DEHUMIDIFYING DRY modes This noise is made by the expansion or contraction of the front panel due to variations in t...

Страница 20: ...www teco com au GBJ PV E OE...

Отзывы: