TECO TWS-TSO26HFFT Скачать руководство пользователя страница 10

8

REMOTE CONTROLLER

Signal 

receptor

+

+

+

Replacement of Batteries  

Remove the battery cover plate from the rear of the remote controller, 
by sliding it in the direction of the arrow.
Install the batteries according the direction (+and -)shown on the Remote 
Controller.
Reinstall the battery cover by sliding it into place.

 Use  2  LRO  3  AAA  (1.5V)  batteries . Do not use rechargeable 
 batteries .  Replace the old batteries  with new ones  of  the  same 
 type when the display is no longer legible. 
 Do not dispose batteries as unsorted municipal waste. Collection
 of such waste separately for special treatment is necessary.

NOTE:if  you adjust the remote controller in cooling mode, 
it will not be possible to activate the heating function in units with 
heating pump . you need to take out the batteries and repeat the 
procedure described above.

1. Direct the remote controller toward the Air conditioner.
2. Check  that  there are no  objects  between  the remote control

and the Signal receptor in the indoor unit.

3. Never leave the remote controller exposed to the rays of the sun.
4. Keep the remote controller at a distance of at least 1m from the

television or other electrical appliances.

Recommendations for locating and using the remote controller  holder (if present) 
The remote controller be kept in a wall-mounted holder

    Refer to picture 2:
    When you insert the batteries for the first time in the remote 
    controller or if you change them, you need to program the remote 
    controller of only cooling or cooling and heating.
    When you insert the batteries, the  symbols       (                )  and
         (                )  start  fashing. If  you  push whatever button when
    the symbol      (               ) is displayed, the remote controller  is  
    adjusted in only cooling mode . If you push whatever button when 
    the symbol      (               )  is displayed , the remote controller is 
    adjusted in Cooling and heating mode.

COOL

HEAT

COOL

HEAT    

Refer to picture 1:
i.

When you open the battery cover, you can see a DIP switch on

the cover back.l

Ii. NOTE:After adjusting the function, you need to take 
    out the batteries and repeat the procedure described above.

 DIP switch on position 

 

Function

 

The remote controller  is adjusted in degree celsius

The remote controller is adjusted in only cooling mode 
The remote controller is adjusted in cooling and heating mode 

The remote controller  is adjusted in degree fahrenheit.

 Cool
 Heat

C

 F

Remote controller holder

M

od

e

Fa

n

Eco

Te

m

p

Sw

ing

Tim

er

Dis

pla

y

Sle

ep

M

ild

ew

Tu

rbo

He

alth

M

od

e

Fa

n

Eco

Tem

p

Sw

ing

Tim

er

Di

sp

la

y

Sleep

M

ild

ew

Tu

rb

o

He

alt

h

Mode

Fan

Eco

Temp

Swing

Tim

er

Display

Sleep

Mute

Tu

rb

o

I Feel

Содержание TWS-TSO26HFFT

Страница 1: ...TECO quality Air Conditioner Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference The design and specifications a...

Страница 2: ...CONTENTS 1 3 4 5 6 9 SAFETY PRECAUTIONS NAMES OF PARTS INDOOR UNIT DISPLAY EMERGENCY FUNCTION REMOTE CONTROLLER OPERATING INSTRUCTIONS OPERATION RANGE MAINTENANCE TROUBLESHOOTING 15 16 17...

Страница 3: ...s such as hair spray lacquer or paint near the unit This may cause re or combustion Do not operate the air conditioner in places near or around combustible gases Emitted gas may collect around the uni...

Страница 4: ...k The product must be properly grounded at the time of installation or electrical shock may occur For all electrical work follow all local and national wiring standards regulations and the Installatio...

Страница 5: ...be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased No Description 13 Air outlet grille Terminal block cover 14 Gas valve 15 Liquid valv...

Страница 6: ...ccording to the model but their function is the same 4 No Led Function 1 2 3 Temperature display Error code 1 Lights up during Timer operation when the air conditioner is operational 2 Displays the ma...

Страница 7: ...operation 2 Two press of the emergency button within 3 sec two beeps will lead to the forced HEATING operation 3 To switch off the unit you just need to press the button again a single long beep 4 Aft...

Страница 8: ...re will decrease 2 on the base of setting temperature Press this button to activate deactivate the Super function which enables the unit to reach the preset temperature in the shortest time In COOL mo...

Страница 9: ...SLEEP indicator 15 TUBRO indicator 16 17 HEALTHY indicator 18 ECO indicator Meaning No Symbols CLOCK indicator 1 2 3 4 5 6 7 8 9 10 11 12 13 14 FEEL mode indicator COOLING indicator DEHUMIDIFYING indi...

Страница 10: ...ons for locating and using the remote controller holder if present The remote controller be kept in a wall mounted holder Refer to picture 2 When you insert the batteries for the first time in the rem...

Страница 11: ...ccidental contact with live pants might cause unforeseeable damage or hurt The air outlet flow is uniformly dist ributed in the room It is possible to position the direction of the air in the optimal...

Страница 12: ...ing function HEAT press the MODE button until the symbol HEAT appears on the display With the button or set a temperature higher than that of the room To optimize the function of theAir conditioner ad...

Страница 13: ...witching on could be read on the display NOTE Before proceeding with the time program the working mode with the button MODE 2 and the fan speed with the button FAN 3 Switch the conditioner off with th...

Страница 14: ...ntrol also stores the speed that was set in the previous mode of operation In FEEL mode automatic the air conditioner auto matically chooses the fan speed and the mode of operation COOLING or HEATING...

Страница 15: ...g the night In cooling or dry mode the set temperature will automatically raise by1 every 60 minutes to achieve a total rise of 2 during the first 2 hours of operation In heating mode the set temperat...

Страница 16: ...e control o measure the temperature at its current location and send this signal 7 times in 2 hours to the air conditioner to enable the air conditioner to optimize the temperature around you and ensu...

Страница 17: ...or after changing the mode during operation this is a normal self protection action you need wait for about 3 minutes The table below indicates the temperature ranges the air conditioner can be opera...

Страница 18: ...ife it till its greatest stroke and then unhooking it from the hinges to make the cleaning easier 2 Clean the indoor unit using a cloth with the water not higher than 40 and neutral soap Never use agg...

Страница 19: ...his occurs when the air in the room becomes very cold for example in the COOLING or DEHUMIDIFYING DRY modes This noise is made by the expansion or contraction of the front panel due to variations in t...

Страница 20: ...www teco com au GBJ PV E OE...

Отзывы: