1.5.2 INSTALLATION AND FUNCTIONING OF THE DEVICE
1) Do not install and do not try to repair the product if it was damaged during transport.
2) Do not connect the power cord to the power supply, unless speci
fi
cally required.
3) In order to ensure the correct working of the device in safe conditions, it is absolutely forbidden to ex-
pose the product to atmospheric agents and to direct heat sources. The temperature of the installation
environment has to be between 5 °C and 38 °C (41 °F – 100 °F).
4) Choose the place foreseen for the installation of the device. It must have the following features:
- It must have openings that allow change of air with the outside.
- The air change must be such to dissipate the heat of the device.
- Make sure that the room temperature does not exceed 38 °C (100 °F) during operation.
5) Place the device by taking into consideration the minimum recommended distances:
6) Lay the tubes as follows:
6.1) Insert the
fi
tting (supplied in the package, including gasket and ring) inside
the pipe, screw clockwise the
fi
tting orienting it as needed and tighten
fi
rmly.
6.2) In connecting the pipes, check that the pipe coming from the pump
and/or from the
fi
lter group (not supplied as standard) is connected in
the position indicated with INLET (Ref.C) and that the return pipe to the
aquarium is connected in the position indicated with OUTLET (Ref.D).
7) Install the appliance in the chosen location allowing for access
to the control and maintenance of the air
fi
lter.
8) Start the pump and make sure that the water circulates regular-
ly within the circuit without any leaks. In case of abnormalities
of the hydraulic circuit or leaks thereof, inspect the connections.
9)
CAUTION:Make sure that the water that reaches the
device is
fi
ltered.
10) Make sure that the electrical power supply requirements correspond to
those shown on the technical data plate, applied on the rear of the device.
11) With the pump in operation, insert the electrical power supply
cable in the electrical current socket and by displacing the elec-
trical switch in position “1”, your device will start operating. The
temperature of water is indicated on the display. To view the tem-
perature to be reached, press the SET key; to return to the water
temperature, press once again the SET key or wait for 5 seconds.
12)
CAUTION: A 2-minutes delay was added to prevent compressor failure at the
fi
rst start.
13) To stop the device, displace the electrical switch in position “0”.
CAUTION: The appliance must be installed at a lower level than the water level.
CAUTION: To prevent damages, the unit cannot operate without water
fl
ow (pump o
ff
).
CAUTION: Do not place the appliance on top of the tank or in a position that allows salty air to be
sucked up into the condenser. CAUTION: Only TK9000 and TK9000H. Connect to the electrical
mains using a circuit breaker as required by current applicable standards. The equipment shall
be connected to a supply having a system impedance lower than 0,24
Ω
.
WARNING: When positioning the appliance, ensure the supply cord is not trapped or damaged.
WARNING: Do not locate multiple portable socket-outlets or portable power supplies at the rear
of the appliance.
Air outlet side (Ref. B)
>500 mm – 19.7 in
Filter side (Ref. A)
>300 mm – 11.8 in
Electrical power supply cable side
(Ref. F)
>60 mm – 2.3 in
Tab. 1-1
B
A
C
D
F
B
E
Содержание TK 9000
Страница 1: ...Instruction Manual TK 3000 TK 6000 TK 9000...
Страница 46: ...44 TANK C H I L L E R L I N E RU 1 2 TECO S r l TECO 1 3 1 3 1 1 2 E 1 4 1 4 1 1 4 2 1 5 1 5 1 1 2 E...
Страница 52: ...50 TANK C H I L L E R L I N E CN 1 3 1 1 2 1 4 1 4 1 1 4 2 1 5 1 5 1 1 2 3...
Страница 58: ...56 TANK C H I L L E R L I N E JP 1 3 1 3 1 1 2 1 4 1 4 1 1 4 2 1 5 1 5 1 1 2 3...
Страница 63: ......