68
5-2 Troubleshooting of Alarm and Warning
Fault Status Digital Output
Alarm
Code
Alarm Name
and Description
Reset
Method
CN1-25
BB/A3
CN1-24
ST/A2
CN1-23
PC/A1
CN1-22
LM/A0
00
Normal
—
If there is no Alarm, CN1-22~CN1-25 operates in
accordance with default function. Please refer to
2-2-1.
01
Under-voltage
Turn
ALRS(DI) ON
1
1
1
0
02
Over-voltage
(Regeneration error)
Turn
ALRS(DI) ON
1
1
0
1
03
Motor Over-load
Turn
ALRS(DI) ON
1
1
0
0
04
Drive Over-current
Reset Power
Supply
1
0
1
1
05
Encoder ABZ phase signal error
Reset Power
Supply
1
0
1
0
06
Encoder UVW phase signal error
Reset Power
Supply
1
0
0
1
07
Multi-function contact setting error
Reset Power
Supply
1
0
0
0
08
Memory Error
Reset Power
Supply
0
1
1
1
09
Emergency Stop
Turn ALRS(DI)
ON
0
1
1
0
10
Motor over-current
Turn ALRS(DI)
ON
0
1
0
1
11
Position error
Turn ALRS
(DI) ON
0
1
0
0
12
Motor over speed
Turn ALRS
(DI) ON
0
0
1
1
13
CPU Error
Reset Power
Supply
0
0
1
0
14
Drive disable
Turn ALRS
(DI) ON
0
0
0
1
15
Drive overheat
Turn ALRS
(DI) ON
0
0
0
0
Содержание JSDEP Series
Страница 14: ...14 Chapter 2 Wiring 2 1 Basic Wiring for Servo System 2 1 1 Wiring for Main Circuit and Peripheral Devices...
Страница 26: ...26 2 3 2 Position Control Mode Pe Mode Open Collector Pe mode External pulse positioning command...
Страница 27: ...27 2 3 3 Position Control Mode Pe Mode Pi Mode Pi mode Internal position command...
Страница 28: ...28 2 3 4 Speed Control Mode S Mode...
Страница 29: ...29 2 3 5 Torque Control Mode T Mode...