EXTERNAL DESCRIPTION

 

FRONT PANEL 

On the front panel there are the control buttons and some leds which indicate the various 

operating mode and alarm conditions. Please see the figures 1 and 2 

OFF button 

To turn off the UPS, press this button for more than one second. 

ON/TEST/ALARM button 

Can be used for 3 functions: 

 

TURN ON: the UPS is turned on by keeping the button continuously pressed for more than 1 

second. 

 

SELF-TEST: the UPS performs a SELF-TEST, according to the procedure explained further on, 

when the button is pressed during LINE mode for more than 1 second. 

 

ALARM OFF: during BATTERY mode, to disable the alarm buzzer, press this button for more 

than 1 second.  

LINE led 

This led (blue) is ON when the input AC line voltage amplitude is within the specification, and it 

indicates the UPS is working in LINE mode. 
If LINE led flashes every second it shows that Phase line and Neutral line of AC input utility line 

are inverted. In that case it must disconnected the AC power input plug from power receptacle, 

turn it at 180 degrees and plug in the power receptacle again 

INVERTER led 

This led (blue) is on when the Inverter is regularly working 

BATTERY led 

This led (blue) is on when the UPS is working in BATTERY mode (during a blackout or 

overvoltage/brownout). 

BYPASS led 

This led (blue) is on when the UPS is working in BYPASS mode: the AC input line is connected 

directly with the UPS outlets. 

FAULT led 

This led (red) is turned on whenever the UPS detects a FAULT condition and needs a technical 

intervention as soon as possible. 

User’s manual 

5 UPS 

EVO

 

Содержание EVO 1.0

Страница 1: ...EVO Uninterruptible Power Supply EVO 1 0 EVO 2 0 EVO 3 0 USER S MANUAL...

Страница 2: ......

Страница 3: ...CEMENT FIRST START UP 5 COMPUTER INTERFACE page 12 6 TECHNICAL CHARACTERISTICS page 13 7 SUGGESTIONS FOR A CORRECT USE page 14 MAINTENANCE BATTERY MAINTENANCE SAFETY FOR THE OPERATOR 8 ANOMALIES AND T...

Страница 4: ...repair or maintenance must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this warning is disregarded It is compulsory to g...

Страница 5: ...ATIC BYPASS that directly connects the AC input line with its outlets EVO is supplied with an RS 232 communication port and USB port which can be used to signal to a generic processor or computer the...

Страница 6: ...ere is an automatic SWITCHING On operation Automatic functioning test through a switch Automatic regulation to the input frequency 50 or 60 Hz Visual warnings by leds indicating operational mode and l...

Страница 7: ...ed This led blue is ON when the input AC line voltage amplitude is within the specification and it indicates the UPS is working in LINE mode If LINE led flashes every second it shows that Phase line a...

Страница 8: ...5 16 17 and 18 60 41 three leds are on led15 16 and 17 40 21 two leds are on led15 and led16 20 0 only one led is on led15 The LOW BAT yellow led led14 is on to warn of a LOW BATTERY condition during...

Страница 9: ...the UPS from the front panel The EPO terminals are isolated and do not need an external feeding voltage REMOTE ON OFF ON 1 2 Remote Button ON OFF 3 4 Remote Button OFF The EVO models have remote ON OF...

Страница 10: ...ormal closed output When UPS works normally Pin 6 and Pin 1 2 will be closed when UPS works in bypass mode Pin 6 and Pin 1 2 will be open 4 AC fail Pin 7 is the normal open output When UPS works norma...

Страница 11: ...gnal showing its own switching on The UPS immediately switches on BAT LEVEL bar then it effectuates an initial operating SELF TEST during which the red FAULT and OVERLOAD leds are switched on it switc...

Страница 12: ...mode is characterized by The BYPASS led and LINE led switched on The LOAD LEVEL and BAT LEVEL led bars switched on The UPS can be transferred in BYPASS mode even through a manual operation First of a...

Страница 13: ...ic signal every second and after it switches automatically to the BYPASS MODE In LINE mode EVO switches automatically to the BYPASS mode as soon as the overload is higher than 150 Once the requested p...

Страница 14: ...put line and to the equipment that needs to be powered The UPS is designed to operate in protected environments for example offices This UPS should be installed indoors with adequate airflow and free...

Страница 15: ...repeat point 4 and 5 6 Carry out the LOAD TEST according the modalities described in charter LOAD CONTROL Carry out step 3 4 5 6 of the initial start up procedure to change the configuration of the de...

Страница 16: ...8 15 minuts AUTONOMY 36 96 96 NOMINAL BATTERY VOLTAGE 3 units 12V 7 2Ah 8 units 12V 7 2Ah 8 units 12V 7 2Ah SEALED MAINTENANCE FREE LEAD ACID BATTERIES TYPICAL BATTERY CHARGE TIME 8 Hours EXPANDABLE A...

Страница 17: ...ioning test in BATTERY mode this will preserve the batteries in an excellent state and extend the life duration Leave the UPS in BATTERY mode until the end of autonomy condition is reached After which...

Страница 18: ...e UPS OFF and remove the UPS input voltage Check the Input Circuit Breaker Should it be snapped OFF position check if the UPS is overloaded then try to rearm the breaker by bringing it in the ON posit...

Страница 19: ...the UPS which are user serviceable Any repair or maintenance work must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this...

Страница 20: ...19 FIGURES Figure 1 Operating modes UPS EVO 18 User s manual...

Страница 21: ...red 2 OFF Button 9 LOAD 100 led blue 10 LOAD 80 led blue 11 LOAD 60 led blue 12 LOAD 40 led blue 13 LOAD 20 led blue Operating modes leds BAT level led bar 3 LINE led blue 14 LOW BAT led yellow 4 BATT...

Страница 22: ...aker 3 Grounded output socket 4 Grounded power output socket EVO 2 0 and EVO 3 0 5 Computer Interface RS 232 6 RJ11 RJ45 IN OUT plugs 7 Slot for external batteries connector 8 Dty contacts board Slot...

Страница 23: ...and in any case any circumstances in which one cannot date back to the defective manufacture will not be covered by the guarantee Compensation is excluded for direct or in direct damages of any natur...

Страница 24: ...TECNOWARE S r l www service tecnoware com...

Отзывы: