Delta UPS – Agilon Family
VX Series, Line-interactive
1000 VA
Installation & Operation Quick Guide
ENGLISH
Package Inspection
1
No.
Item
Q'ty
1
UPS
1 PC
2
Quick Guide
1 PC
3
USB Cable
1 PC
4
Output Power Cord (10A)
1 PC
Remove the UPS from its package and inspect it for damage that may
have occurred during shipping. If any damage is discovered, re-pack
the unit and return it to the place of purchase.
Front Panel & Rear Panel
2
No.
Item
1
LCD Touch Panel
2
ON/ OFF Button
3
Output Socket
4
AC Input
5
Circuit Breaker
6
USB Port
Operation
3
y
y
Placement
Install the UPS in a protected area that is free of excessive dust and
has adequate air flow. Place the UPS away from other units at least
20 cm to avoid interference. For best performance, keep the indoor
temperature between 0° C and 40° C.
y
y
Connect to Utility Power
Connect the AC power cord to the utility power. Then, the UPS will
start to charge its inside battery (batteries). For best result, charge the
battery (batteries) for 6 hours prior to initial use. It is not recommended
to connect the UPS’s AC power cord to any generator.
y
y
Plug in Equipment
Plug your equipment to the Output Socket on the rear panel of the
UPS.
NOTE:
Make sure that the UPS is powered on to protect all important
devices from data loss during power failure.
WARNING:
NEVER
connect a laser printer or scanner to the Output
Socket of the UPS. The equipment may draw significant
power to overload the UPS.
y
y
Connect to USB Port and Install Software
Connect one end of the supplied USB cable to your PC and the other
to the USB port located at the rear of the UPS. Download the latest
version of ViewPower software (http://www.deltapowersolutions.com/
en/mcis/600va-1500va-single-phase-ups-vx-series-software-download.
php) to your hard drive. Follow on-screen instructions to complete the
software installation.
y
y
Turn On/ Off the UPS
When the UPS is OFF, press the ON/ OFF Button to turn on the UPS
and the LCD will be on. When the UPS is ON, press the ON/ OFF
Button to turn off the UPS and the LCD will shut off.
y
y
Storage
All connected equipment should be turned off, then disconnect from
the UPS to avoid battery drain. Unplug the UPS from the wall outlet.
Then turn off the UPS for storage. Store the UPS unit covered and
upright in environments where the ambient temperature is -20°C to
50°C with its battery fully charged.
Continue to the Next Page
LCD Display
4
y
y
Operation Display:
UPS Mode
LCD Touch Panel
Description
UPS
Power On
When the UPS is powered
on, it will enter this mode
for 4 seconds.
AC Mode
When AVR is functioning,
icon will flash every
second.
LCD information will be
displayed in the following
order when the LCD
is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
In AC
Mode
icon will flash.
When overload occurs,
alarm will beep every 0.5
second.
Battery
Mode
When battery level is low,
icon will flash.
Alarm will beep every
10 seconds and LCD
information will be
displayed in the following
order when the LCD
is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
In Battery
Mode
icon will flash.
When overload occurs,
alarm will beep every 0.5
second.
NOTE:
If backlight shuts off, you can activate it by touching the screen.
y
y
Fault Code Table:
Fault Condition LCD Touch Panel
Solutions
Output Short
Circuited
Disconnect short-circuited
loads and restart the UPS
again.
Overload Fault
Disconnect all output loads
and restart the UPS again.
Over Charge
Fault
Call for service immediately.
Battery Too Low
Fault
Please replace the battery
(batteries).
Battery Mode
Output High Fault
Call for service immediately.
Over
Temperature
1. Turn off the UPS and wait
for cooling.
2. Or remove excessive
loads and wait for cooling.
If any fault alarm occurs, please call for service immediately.