www.deltapowersolutions.com
Technical Specifications
7
Model
1000VA
Capacity
1kVA/600W
Nominal
Input Voltage
230 Vac
Input Voltage Range
170 ~ 280 Vac
Output Voltage
230 Vac ± 10% (Bat. mode)
Transfer Time
Typical 2 ~ 6 ms
Waveform
Simulated Sine Wave
Battery Type & No.
12V/7Ah x 2
Charging Time
Typical 6 ~ 8 hours
Dimensions
(D x W x H)
320 x 130 x 182 mm
Net Weight (kgs)
8.2
Humidity
0 - 90% RH @ 0 - 40°C (non-condensing)
Noise Level
Less than 40dB
* Specifications are subject to change without notice.
Warranty
8
Seller warrants this product, if used in accordance with all applicable
instructions, to be free from original defects in material and workman-
ship within the warranty period. If the product has any failure problem
within the warranty period, Seller will repair or replace the product at its
sole discretion according to the failure situation.
This warranty does not apply to normal wear or to damage resulting
from improper installation, operation, usage, maintenance or irre-
sistible force (i.e. war, fire, natural disaster, etc.), and this warranty
also expressly excludes all incidental and consequential damages.
Maintenance service for a fee is provided for any damage out of the
warranty period. If any maintenance is required, please directly contact
the supplier or Seller.
WARNING:
The individual user should take care to determine prior to
use whether the environment and the load characteristic are
suitable, adequate or safe for the installation and the usage of
this product. The Quick Guide must be carefully followed. Seller
makes no representation or warranty as to the suitability or
fitness of this product for any specific application.
Safety Caution
5
SAVE THESE INSTRUCTIONS-This quick guide contains important
instructions that should be followed during installation and
maintenance of the UPS and battery (batteries).
y
y
The UPS utilizes voltage that may be hazardous. Do not attempt
to disassemble the unit. The unit contains no user replaceable
parts. Only factory service personnel may perform repairs.
y
y
This pluggable type A equipment with battery (batteries) already
installed by the supplier is operator installable and may be oper-
ated by laymen.
y
y
The mains socket outlet that supplies the UPS shall be installed near
the UPS and shall be easily accessible.
y
y
During the installation of this equipment it should be assured that
the sum of the leakage current of the UPS and the connected loads
does not exceed 3.5mA.
y
y
Connection to any other type of receptacle other than a two-pole,
three-wire grounded receptacle may result in shock hazard as well
as violate local electrical codes.
y
y
In the event of an emergency, press the ON/ OFF Button and dis-
connect the power cord from the AC power supply to properly dis-
able the UPS.
y
y
Do not allow any liquid or any foreign object to enter the UPS. Do
not place beverages or any other liquid-containing vessels on or
near the unit.
y
y
The unit is intended for installation in a controlled environment (tem-
perature controlled, indoor area free of conductive contaminants).
Avoid installing the UPS in any location where there is standing or
running water, or excessive humidity.
y
y
Do not plug the UPS input into its own output.
y
y
Do not attach a power strip or surge suppressor to the UPS.
y
y
Do not attach non-computer-related items, such as medical equip-
ment, life-support equipment, microwave ovens, or vacuum cleaners
to the UPS.
y
y
Do not dispose of battery (batteries) in a fire as they may explode.
y
y
A battery can present a risk of electrical shock and high short circuit
current. The following precautions should be observed when working
on batteries:
1. Remove watches, rings, or other metal objects from the hands.
2. Use tools with insulated handles.
3. Wear rubber gloves and boots.
4. Do not lay tools or metal parts on top of battery (batteries).
5. Disconnect charging source prior to connecting or disconnecting
the terminals of battery (batteries).
y
y
Internal battery voltage is 12Vdc. Battery type is sealed, lead-acid,
6-cell battery.
y
y
Servicing of batteries should be performed or supervised by person-
nel knowledgeable of batteries and the required precautions. Keep
unauthorized personnel away from batteries.
y
y
When replacing battery (batteries), replace with the same number
and type of sealed lead-acid battery (batteries).
y
y
Do not open or mutilate the battery or batteries. Release electrolyte
is harmful to the skin and eyes. It may be toxic.
y
y
Attention! Hazardous through electric shock. Even disconnection of
this unit from the mains, hazardous voltage still may be accessible
through supply from the battery (batteries). The battery supply should
be therefore disconnected in the plus and minus pole at the connec-
tors of the battery (batteries) when maintenance or service work inside
the UPS is necessary.
y
y
To reduce the risk of overheating the UPS, do not cover the UPS’s
cooling vents and avoid exposing the unit to direct sunlight or install-
ing the unit near heat emitting appliances such as heaters or furnaces.
y
y
Unplug the UPS prior to cleaning and do not use liquid or spray deter-
gent.
Troubleshooting
6
Problem
Possible Cause
Solutions
Nothing is
displayed
on the LCD
panel
The UPS is not on.
Press the ON/ OFF Button again
to turn on the UPS.
Battery voltage is too
low.
Charge the battery (batteries) at
least 6 hours.
Battery fault.
Replace the battery (batteries).
The UPS
always runs
in battery
mode.
The power cord
becomes loose.
Re-plug the power cord.
The circuit breaker is
tripped.
Reset the breaker.
The UPS
continuously
beeps.
Please check the
Fault Code Table
for
the details.
Please check the
Fault Code
Table
for the details.
Backup time
is too short.
Battery voltage is too
low.
Charge the battery (batteries) at
least 6 hours.
Overload.
Remove some unnecessary
loads. Before reconnecting
equipment, please verify that the
load matches the UPS capability
specified in the specs.
Battery defect.
Replace the battery (batteries).
If any abnormal situations occur that are not listed above, please call for
service immediately.
Copyright © 2019 by Delta Electronics Inc. All Rights Reserved.
This Quick Guide is subject to change without prior notice.
Version Date : 2019_02_27