HYDRO
BOX
Pag
. 11
TECNOVAP 36/18
CONTROL PANEL FUNCTIONS
Indicator for pump in standby
Indicating pump operation: if blinking the pump is in standby mode (occurs after about 40
seconds of inactivity).
Temperature switch
Activates/disactivates: possibility of temperature regulation.
Indicator for lack of water
Indicating lack of water in the boiler: blinking with simultaneous intermittent acoustic signal.
Boiler switch/ Temperature reduction
Activates/disactivates the heating elements of the boiler.
If the temperature switch is activated, the operating water temperature can be reduced.
Indicator for Boiler switched ON
Indicating that the boiler is switched on.
Pump switch / Temperature rise
Activates/disactivates the high-pressure pump.
If the temperature switch is activated, the operating water temperature can be increased.
Indicator for high-pressure pump switched ON
Indicating that the high-pressure pump is switched on.