2. Maintenance of the regenerator and of the filter (every
1,500 hours).
Remove the filter in front of the regenerator.
Pull the cord of the regenerator in order to remove the
regenerator from the air duct.
Take care when extracting the regenerator to avoid
damaging it. Remove the filter behind the regenerator.
Clean the filter when it is dirty (every 1,500 hours).
When the 1,500 hour operation period ends, a red indicator
LED lights up on the fan as a reminder of the need to
replace or clean the filter. The signal is repeated until the
maintenance has been completed.
Clean the filters, let them dry and insert the dried filters in
the duct.
Extraction is allowed.
The life span of the filters is of about 3 years.
For spare filters, contact the seller.
Even regular maintenance cannot fully prevent the
accumulation of dirt on the regenerator group.
Clean the regenerator regularly to ensure high efficiency
heat exchange.
Clean the regenerator with a vacuum cleaner at least once
a year.
In order to reset the operation time meter, insert the filters
and the regenerator in the fan, then keep the ON/OFF
button pressed for 5 sec. and when you hear a prolonged
sound, release it.
3. Maintenance of the external grille (once a year).
The external ventilation grille can get blocked by leaves or
other objects which prevent the unit from working properly.
Check the ventilation grille twice a year and clean it whenever
necessary.
To clean the ventilation grille, remove it, then clean the air
duct.