Tecnosicurezza DeadBolt T4800/D Скачать руководство пользователя страница 13

 

 

 

     
 
 

II_PulsePro_05_eng 

 

 

 

 

 

                13 of 20 

Installation instructions 

Pulse PRO 

Cut the spindle to the correct length (measure door thi mounting plate/rotation knob or 
handle  lock spindle insert). 
Remove any cutting residues of the spindle that could damage the cable. 
 

 

 

 

 
It’s possible to connect a relocker to the lock cover through the appropriate holes. 
 

 

 

T4801/D & T4801/S locks 

 

The spindle needs to be fully inserted inside the lock (7 mm).

 

 

Place the cable in the groove of the spindle, making sure it’s fully inserted and locked. 

Secure the cable inside the special groove located under the lock 
body, ensuring that it is not stretched when turning the spindle. Fix 
the lock using the appropriate mounting screws. 

 

 

 

Connect  the  keypad  cable  to  the  lock  connector  "1",  making  sure  it  is  fully  inserted  and 
locked. Any alarm interface or battery holder needs to be connected to the lock connector 
“2”. To remove the cable, bring the connector upwards and carefully pull it out. 

T4800/D & T4800/S locks 

 

The spindle must be inserted between a minimum of 7 mm to a maximum of 12 mm inside  
the lock. 

WARNING: do not insert the spindle up to the lid of the lock, but leave some margin to  
allow the movement of the cable and to prevent any damage 

 

Place the cable in the groove of the spindle, making sure it’s fully inserted and locked. 
Insert the cable connector into the square hole present in the bottom of the lock and make it 
come out from the opposite side. 

Secure the cable inside the special groove located on the lock 
cover, ensuring that it is not stretched when turning the spindle. 
Fix the lock using the appropriate mounting screws. 

 

 
   

 

Connect the keypad cable to the lock connector "ENT", making sure it is fully inserted and 
locked. Any alarm interface or battery holder needs to be connected to the lock connector 
“BAT”. To remove the cable, bring the connector upwards and carefully pull it out. 

Fix the relocker plate with M4 self tapping flat head screws. 
Length must be 6mm + plate thickness.  

 

 (i.e. 6mm + 2mm plate = 8mm screw)  

 

Содержание DeadBolt T4800/D

Страница 1: ...Pulse Pro Installation instructions...

Страница 2: ...LOCK DIMENSIONS 7 LATCHBOLT LOCK DIMENSIONS 7 MOTORLOCK LOCK DIMENSIONS 8 MOTOR LATCHBOLT LOCK DIMENSIONS 8 KEYPAD ROTATING KIT INSTALLATION INSTRUCTIONS ACCESSORY P N T3300 9 FIXED KEYPAD INSTALLATIO...

Страница 3: ...NL1000 Mounting adapter T20019 T Cabling interface Adapter L4001 Large battery box for 6 size C 1 5V batteries N620 A 9V Battery box with alarm interface T6006 Power supply interface 12 24 V with alar...

Страница 4: ...Bolt and MotorLock locks can be mounted behind the passage hole for the connection cable or the spindle Any electronic part must be properly protected and not easily accessible even when the door is o...

Страница 5: ...oad must not exceed 4 N for T4801 M and 30 N for reinforced model T4801 MP Secure the cables away from moving parts by using cable ties and cable ties bases If placed in normal domestic or office envi...

Страница 6: ...6 of 20 II_PulsePro_05_eng Installation instructions Pulse PRO Keypad dimensions SwingBolt lock dimensions T4801 T4800...

Страница 7: ...II_PulsePro_05_eng 7 of 20 Installation instructions Pulse PRO DeadBolt lock dimensions T4801 D T4800 D LatchBolt lock dimensions T4801 S...

Страница 8: ...8 of 20 II_PulsePro_05_eng Installation instructions Pulse PRO T4800 S MotorLock lock dimensions T4801 M T4801 MP Motor LatchBolt lock dimensions T4801 M S...

Страница 9: ...ble holes Fix the screws M4 and the rotating backplate positioning the latter on the side marked UP Fix the bushings to the keypad housing using the supplied screws Insert the pin completely in the sp...

Страница 10: ...d case Connect a battery to the battery connector inside the keypad battery compartment or if provided connect the battery pack to the lock connector 2 BAT SwingBolt lock installation instructions The...

Страница 11: ...ock cover through the appropriate holes DeadBolt and LatchBolt locks installation instructions DeadBolt and LatchBolt are locks with respectively a dead bolt and a spring bolt whose block is carried o...

Страница 12: ...tween the lock bolt and the blocking bar of the boltwork The maximum load applicable to the bolt must not exceed 1 KN Contact Tecnosicurezza in case of heavier loads The LatchBolt lock is specially de...

Страница 13: ...able bring the connector upwards and carefully pull it out T4800 D T4800 S locks The spindle must be inserted between a minimum of 7 mm to a maximum of 12 mm inside the lock WARNING do not insert the...

Страница 14: ...ounting directions RH LH VU VD Locks is supplied with metric M6 mounting screws Upon request Imperial 1 4 20 UNC format mounting screws are available The Motor LatchBolt lock is specially designed to...

Страница 15: ...he bolt must not exceed the limit values specified in the table below Contact Tecnosicurezza in case of heavier loads Lock reference Lock version Maximum force to apply on the bolt Maximum load pulled...

Страница 16: ...turn the safe door handle to the open position With DeadBolt and LatchBolt locks rotate the knob or keypad according to the type of installation and move the lock bolt to the open position For all ty...

Страница 17: ...guenti norme armonizzate EN 61000 6 3 EN50130 4 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 11 EN 61000 6 1 EN55022 The undersigned Mr Franco Miller as Chairman and Leg...

Страница 18: ...orme armonizzate EN 61000 6 3 EN50130 4 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 11 EN 61000 6 1 EN55022 The undersigned Mr Franco Miller as Chairman and Legal Repre...

Страница 19: ...II_PulsePro_05_eng 19 of 20 Installation instructions Pulse PRO NOTES...

Страница 20: ...lled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Contacts GLOBAL HEADQUARTERS USA HEADQUARTERS SPAI...

Отзывы: