12 of 20
II_PulsePro_05_eng
Installation instructions
Pulse PRO
In the locked position, there should be approximately 1 mm
clearance between the lock bolt and the cavity in the blocking
bar of the boltwork. The bolt must be able to move freely
without force being applied to it.
In open position, there should be a minimum of 3mm and maximum of
5 mm clearance between the lock bolt and the blocking bar of the
boltwork.
The maximum load applicable to the bolt must not exceed 1 KN. Contact Tecnosicurezza in case of
heavier loads.
The LatchBolt lock is specially designed to ensure self locking when the door closes.
T4801/S
The distance between the lock and the locking edge must be between a
minimum of 6 mm and a maximum of 10 mm.
The distance between the lock and the locking edge must be
between a minimum of 3 mm and a maximum of 8 mm.
T4800/S
When locked, there must be a 0.5 mm gap between lock bolt and
locking surface.