![Tecnoplastic CRAB Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/tecnoplastic/crab/crab_instructions-manual_1072017003.webp)
ENGLISH
NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING
POINTS WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT
Ÿ
Before any opera on on the float remember to disconnect the power supply from the main power.
Ÿ
Check that the maximum motor power does not exceed the float's electrical values.
Ÿ
In case of cable damage by the final user or installer, the float must be replaced.
Ÿ
Do not make any joint on the cable of the float switch, as immersion of such joints could cause short
circuits or electrical shocks.
USE:
The electronic controller is designed to work in clear and rain water. Supported on a flat surface, it remains
anchored to the bo om. It can detect the presence of water at 3mm ±1 from the floor.
The electronic regulator has two delay mes: start and stop (shutdown) which can be adjusted by the final
customer according to his needs of use. And thanks to the Schuko Piggy Back Plug (accessory sold
separately) it can be connected directly to a pump without the need of a tradi onal electronic panel.
TECHNICAL FEATURES:
Features of automa c ac on: 1B (micro-disconnec ons in opera on) - Pollu on Degree: 2
SET DELAY TIMES:
The first me you connect the plug to the electrical system, the electronic controller will perform a 5
seconds startup test to check the func oning.
Factory default delay me:
Ÿ
Star ng Delay Time: 5 seconds.
The pump turns on 5 seconds a er the water has raised touching the
two sensors placed at the bo om of the electronic regulator.
Ÿ
Shutdown Delay Time: 30 seconds.
The pump turns off 30 seconds a er the water has flowed down
releasing the sensors.
Change the
1
. Disconnect the plug from the electrical system
2.
Put the
Star ng/Delay Time (Fig.1)
magne c key close to the
arrow
stamped on the side of the electronic controller.
3.
Connect the plug to turn
on the pump.
4.
Hold the magne c key in posi on for how many seconds you wish to delay the star ng me
(maximum 120 seconds)
.
5.
Once you got the desired delay me, remove the magne c key.
Change the
1.
Connect the plug to the electrical system.
2.
Wait for the pump
Shutdown Delay Time (Fig.2)
shutdown.
3.
Put the magne c key close to the
arrow
shown on the side of the electronic regulator and the
pump starts.
4.
Hold the magne c key in posi on for the seconds necessary to delay the shutdown
(maximum 120 seconds)
.
5.
Once reached the desired me, remove the magne c key.
Connec on without plug
M
Grey
Yellow
/
Green
Black
Brown
N
L
Connec on with Schuko Piggyback plug
Brown
Grey
Black
Yellow
/
Green
L
N