Manuale d’istruzione per l’installazione, la manutenzione e l’uso
Pentole a gas P70.G7 / P8.G7
05.11.01 - IT
pagina
31
1.2. TECNICAL DATA
Table 1
– General data
Note:
Models with "A" as end letter = pressure kettle
Model
Type of
heating:
Vat usable
volume: I
Pressure in the vat:
bar
Jacket pressure:
bar
P70DG7
P8DG7
Direct
50
--
--
P70IG7
P8IG7
Indirect
50
--
0,5
Table 2
– Sizes
(
see figure “
Size of appliance and position of connections
”)
Specifications
Models
Description
Unit of
measurement
P70.G7 / P8.G7
Width (A)
mm
700
Depth (B)
mm
700
Height (C)
mm
900
Vat diameter
mm
400
Table 3
– General water data
Specifications
Models
Description
Unit of
measurement
P70.G7 / P8.G7
Cold water connection
mm
10
Hot water connection
mm
10
Water pressure
kPa
50
– 300
Table 4
– Minimum output setting
P70.G7 / P8.G7
G 20
– 20 mbar
4,5 mbar
G 30
– 28-30/37 mbar
7 mbar