20
USER AND MAINTENANCE MANUAL
1_30_______FEET POSITIONING AND ADJUSTMENTS
Place the refrigerated table in a complete horizontal position,
if necessary turn the adjustable screw feet
on the legs of the unit to adjust to the desired level;
use a spirit level to make sure is flat.
The unit must be in
a complete flat position in order to work properly and to allow proper drainage of condensed/defrosting water;
the position will also help avoid noisy motor vibrations. Make sure the condensed water drainage container and
its respective drain are positioned correctly
.
1_35_______INSTALLING THE UNIT INSIDE THE POINT OF SALE
It is advisable to install the refrigerated table inside an area with an air conditioning system. Please note that malfunctions may
arise in areas that are not provided with air conditioning, e.g. condensation formation… etc.
Please pay special attention to the following guidelines for correct operation of the refrigerated table:
•
Do not position the unit in an area directly exposed to sun light or to other heating sources,
such as high intensity
incandescent lighting systems, ovens or other radiant heating sources, e.g. heating radiators etc.
•
Do not position the unit nearby door openings producing air currents,
whether doors or windows or directly exposed
to air from fans, vents or fan coil unit air conditioner.
•
Do not block or obstruct the air inlets of the monoblock unit or condensing unit
.
•
Do not place any objects on the unit, including boxes or any other type of objects; leave the entire perimeter of
the unit completely free
so that air can circulate properly.
•
Do not place the refrigerated table inside areas with high relative humidity levels
(it may cause formation of conden-
sation)
•
Do not position the refrigerated table inside a closed niche,
as there is not enough air circulation and may cause the
refrigeration unit to not work proper
Make sure there is enough air circulation in the area, even during closing hours. This will allow the monoblock unit /
condensing unit
to work properly.
1_40_______MINIMUM WALL DISTANCE
In order for the unit to work properly with adequate air circulation,
when placing the table,
make sure to comply with the
MINIMUM wall distances,
as indicated below:
•
keep a MINIMUM distance of 60 cm from the front part of the motor grill of the unit
•
keep a MINIMUM distance of 10 cm from the back of the unit to the wall; this will prevent formation of condensa-
tion.
fig. 1