background image

IST-2292.PM01.01

 

Istruzione / User’s Manual / Manuel d’utilisation 

Pag.10/10

 

 

 

 

TECNOCONTROL S.r.l. Via Miglioli 47 SEGRATE ( MI ) 

Tel. +39 02 26922890 - Fax +39 02 2133734

 

 

 

 

Fig. 1 –

 

Dimensioni /

 Size / Dimensions 

 

 

Fig. 2 -

 

Schema di collegamento 

/ Wiring diagram / Schéma

 

12

-2

4V

 

m

A

 

1

 

2

 

3

 

4

 

ON

 

OFF

 

SET

 

Test Uscita  

Output Test 

Sortie Test 

40÷200mV

 

 

TESTmA

 

+/- 

(12÷24Vdc)

 

Alimentazione / Power Supply / Alimentation

 

Centrale rivelazione gas 

Gas Central Unit

 

Centrale de détection

 

RL

 

-

 

S

 

“S” 

Uscita 4÷20 mA 

4÷20 mA Output / Sortie en 4÷20 mA

 

Dip Switch

 

+

 

mV

 

 

 

Fig. 3 -

 Tester di calibrazione 

/ Calibration Tester / Kit de Calibration 

0,3L/min

 

F1 

F2 

Tasti / 

Key / Touches

 

 

 

Alimentazione 

/ Power Supply / Alimentation

 

100

 

300

 

400

 

500

 

50

 

0

 

5

 

200

 

Vdc

 

RL=Resistenza di carico 

/ Load resistor / Resistance de charge

 

RL

 

Ohm

 

Fig.4 -

 

Alimentazione / Resistenza di Carico 4÷20mA 

Power supply / Load resistance diagram 4÷20mA 
Alimentation / Résistance de charge 4÷20mA

 

600

 

0

 

10

 

15

 

20

 

25

 

28

 

650

 

10,8

 

24

 

Area di funzionamento 

Allowable oparating region 

350

 

700

 

800 

 

Содержание TS292P

Страница 1: ... 20 mA lineare Linear linéaire Resistenza di carico load resistor résistance de charge 50 ohm 12Vdc 10 500 ohm 24Vdc 10 Campo di misura Standard Range Champ de mesure 0 100 LIE LEL Limite Scala Limits Limite échelle 100 LIE LEL Vita media in aria pulita Average Life in fresh air Vie moyenne en air pur 5 anni years ans Tempo di risposta Response Time Temps de réponse T90 60 secondi seconds secondes...

Страница 2: ...d Rosso ALARM si accende se è stato abilitato se la concentrazione di Gas supera il 20 LIE I Guasti possibili sotto elencati sono indicati dall accensione del Led giallo FAULT e portando l uscita S a 0mA Il Led Giallo si accende ogni 4 secondi con il Led Verde acceso per avvisare che la Cartuccia Sensore ha su perato il suo limite di vita circa 5 anni e non è più garantito il corretto funzionament...

Страница 3: ...nza è automaticamente cancellata Kit di Taratura e Bombole con Miscela Aria Gas per Calibrazione e Verifica la miscela da utilizzare è Gas Meta no al 20 LIE 0 88 v v in aria 20 9 Ossigeno circa in quanto i sensori catalitici Pellistor non possono assoluta mente funzionare in assenza d ossigeno È possibile usare sia bombole monouso con valvola d erogazione sia ri caricabili ad alta pressione con ri...

Страница 4: ...M Methane CH4 is calibrated to detect Methane a gas lighter than air Its density as to air is 0 55 and its LEL Lower Explosive Limit is 4 4 v v volume TS292PG GPL is calibrated to detect LPG a gas heavier than air and consists of a mixture of 20 30 Propane C3H8 and 80 70 Butane C4H10 Propane density as to air is 1 56 while Butane is 2 05 The LEL is 1 7 v v for Propane and 1 4 v v for Butane Standa...

Страница 5: ...listor sensor operates only in presence of Oxygen Do not use pure gases or a lighter directly on the sensor since they could damage it irremediably Warning some substances cause a permanent reduction in sensitivity Avoid contacts of the sensor with vapours of Silicone compounds Tetra ethyl Lead petrol antiknock additive and Phosphate esters since they can reduce irremediably its sensitivity Some s...

Страница 6: ...olumn 8 If the result is different is necessary to recalibrate the sensor see Calibration Then close the gas bottle remove TC011 Then the mA output will slow ly decrease up to 4mA Using a cylinder with the specific gas Air mixture the output signal will correspond to the gas used Example if you have to verify a hydrogen detector using a cylinder with H2 at 0 8 v v 20 LIE in air the mA output will ...

Страница 7: ...angers d explosions et les normes de sûreté des installations Montage en Fig 1 sont indiquées les dimensions Le détecteur doit être monté en position verticale avec le capteur tourné vers le bas Positionnement du TS292PM il doit être fixé à environ 20 30 cm du plafond le gaz méthane étant plus léger que l air Positionnement du TS292PG il doit être fixé à environ 20 30 cm du plancher le gaz GPL éta...

Страница 8: ...a sortie en mA est supè riere a 10 de la LIE 5 6 mA Dans le cas il nécessaire de procéder a la calibration ou bien de substituer la car touche ETALONNAGE Code de Etalonnage F2 F2 F2 F1 F2 F1 cette fonction permet l étalonnage du capteur Le mélange à utiliser est le mélange méthane 20 LIE 0 88 v v en air 20 9 oxygène environ Durant la procédure une rare possibilité existe que la LED Jaune clignote ...

Страница 9: ... Air 1 NOTA 1 NOTE 1 REMARQUE 1 20 LIE LEL v v TESTmA TP1 TP2 mV Uscita Output Sortie mA LIE LEL TS292PM Metano Methane Méthane 1 4 4 0 55 0 88 72 7 2 20 TS292PG Butano Butane Butane 1 43 1 4 2 05 0 28 89 8 9 31 TS292PI Idrogeno Hydrogen Hydrogène 1 54 4 0 07 0 8 72 7 2 20 TS292PB Benzina Petrol Essence 0 91 1 2 2 8 0 24 89 8 9 31 TS292PX Acetato di etile Ethyl acetate 1 67 2 2 3 04 0 44 95 9 5 34...

Страница 10: ...velazione gas Gas Central Unit Centrale de détection RL S S Uscita 4 20 mA 4 20 mA Output Sortie en 4 20 mA Dip Switch mV Fig 3 Tester di calibrazione Calibration Tester Kit de Calibration 0 3L min F1 F2 Tasti Key Touches Alimentazione Power Supply Alimentation 100 300 400 500 50 0 5 200 Vdc RL Resistenza di carico Load resistor Resistance de charge RL Ohm Fig 4 Alimentazione Resistenza di Carico ...