WELDERS ITEM 8201N ÷ 8214N
EDITION: MAY 2008 PAGE 24 OF 32
FAULT
CAUSE
REMEDY
By
pressing
foot-control
device the electrode descends
but does not weld. Electrode
rises up only when releasing
the foot-control.
The
foot-control
device
enables
the
micro-switch
START
but
not
the
AUXILIARY one. The control
unit
AUXILIARY
led
switches on when pressing
foot-control and keeps on until
it is released.
Check both the foot-control
connections and corresponding
micro-switches.
Check
cams
positioning
inside
the
foot-
control.
The welder unit carries out the
welding cycle without current
circulation. The control unit
CURRENT
led
,
if
present, lights.
Thermostat ST1 placed on
SCR activated.
Check that water circulates in the
required quantity and/or check
the correct thermostat working.
Either SCR or firing module
wrong
functioning.
Firing
modules
led
shows
the
presence
of
SCR
trigger
signals.
Identify the faulty component
and replace it.
Faulty
contact
in
the
secondary circuit
Check
and
tighten
all
the
secondary connections. Do not
forget
the
electrode
and
electrode-holder connection
No electrode descent. Control
unit led
START is on.
Welding control unit display
shows
”THERMOSTAT
ACTIVATED”
Inadequate
or
no
water
circulation. Thermostat ST2
placed on welding transformer
activated or flow switch SF1
(optional) activated.
Check that water circulates in the
required
quantity.
Eventually
calibrate the Flow-switch, or
check the correct thermostat
working.
No
electrode
descent.
Welding control unit led
EV1 lights.
Leak of compressed air.
The corresponding manometer
shows it. Operate.
Welding pressure inadequate. The corresponding manometer
shows it. Increase it by means of
the pressure regulator.
Broken connection between
the control unit and the
solenoid valve.
Check.
Faulty solenoid valve EV1.
Replace it