9
Starting Operation and Use
Check if the data on the nameplate is corresponding with the actual mains voltage. Instrument
scheduled for 230V can be plugged to 220V/240V mains.
Improper use may damage the Instrument. Observe therefore these instructions:
o
Use just mixing paddles up to the specified diameter.
o
Load the instrument in such a way that the speed would not drop considerably or that it would
stop.
Fixing mixing-paddles:
Push down the chuck by hand; connect the paddles (64) HEX 13 into the spline shaft directly and than
loose your hand.
Switching On and Off:
By pressing the switch button (20) the stop and simultaneous pressing the arresting pin
the machine is brought into operation and it stops when this is relieved.
Maintenance
o
This power tool normally requires no maintenance; from time the ventilation holes on the
motor housing (3) should be cleaned out.
o
After approx. 50 hours of operation, check the motor brushes and replace if necessary. Clean
the motor housing.
o
After approx. 200 hours of operation, renew the grease filling in the gearbox.
To verify that the protective insulation remains intact, the machine must be subjected to a technical
safety test afterwards. For this reason, this work must be performed exclusively by a professional
workshop.
Environment Protection
Do not open worn out machines and return to the collection facilities provided for recycling.
Storage
The unit should be stored in a dry place where it is protected against freezing.