Sirio HH
Use and maintenance manual
Page 8 of 28
Instruction n°
192
- Rev.
02
of 06/07/2016
EN
Copyright © 2016 Tecmec S.r.l.
Translated from the original instructions
3
S
AFETY
3.1
Safety rules
The products of the series Sirio HH, must be included in the assessment of company risk and requires the
applicable laws on safety at work to be complied.
To ensure the highest possible degree of safety in the correct use of the machine, all measures deemed
necessary in the design, construction, testing and installation have been adopted.
For a proper use, the machin has to be used by trained personnel, in order to avoid accidents.
The used components is in accordance with the applicable standards.
The dispenser Sirio HH Compact must be located in a special tank / container, suitable to contain any
accidental products leaks.
To avoid that the equipment have instability issues, it's necessary to verify both the perfect
leveling of the feets locaded in the bottom part of the structure and the fixing to the wall, as
per the assembly instructions.
3.2
Electrical power supply
Determined the installation area, the following prerequisites have to be implemented:
The main power supply have to be provided through an electrical panel, placed on the wall close to the
equipment.
The maximun expected power is 0.75Kw.
The section of each conductor must be a minimum of 1,5 mm².
The main power supply line, must be fitted with an efficient ground connection, and complies with all
the requirements in force.
The electrical power supply panel have to consist in a residual current device (IΔn=0,03A) with voltage
and phase compatible with the agitation motor (single phase).
To ensure a complete safe operation for the operator and the equipment, it's very important, during the
assembly of the electrical panel, to use the above mentioned type of switch, due to the fact that the switch
will have a protective function against possible direct or accidentals voltage hazard down to ground.
It's important to make the necessary assessment of the site, and follow the requiring and characteristic rules
of the electrical system, to ensure that they are not a cause of accidents or injuries.