S1
GRD
COM
NO
NC
• COM
: This port is your
12vDC input
from your
power supply. Since
this is the same section
as where your locks
would go you can refer
to
Section 06
for further
information.
• NO
: This is the port
where you will connect
the +12VDC for the
alarm you choose.
Connecting to this port
will start your alarm
and provide indication
of when the door is
unlocked.
• GRD
: This port is where
you would connect the
Ground
wire from the
alarm. You can also
run the ground cable
to the Power Supply if
the port is getting too
congested.
You can use these devices for multiple applications. For example, you can use a light above
the door to indicate that it is unlocked, informing someone trying to enter or exit that they can
do so. This is a good solution for low light situations. Another example, which can be used
in conjunction with a Push-To-Enter button, when the button is pressed a buzzer alerts the
person that the door is now unlocked and can be opened. These ideas and more can be used
separately or together to create customizable experiences for you and your client.
Just remember, if you connect these devices, when you leave the door unlocked the buzzer
will continue to go off. A simple relay connected to the Push-to-Enter button will work better
for that installation. Please call our tech support for further instruction.
Connecting a Siren, Buzzer, or Light
Location On Board
Access Control can allow you to do some impressive things to help indicate
the door is open or closed. Below will explain how to connect these devices.
Page#