![Techsphere VP-II X Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/techsphere/vp-ii-x/vp-ii-x_user-manual_1070885021.webp)
21
When the duress verification is made, the VP-II X can send an alarm event in three ways 1) it sends to
NetControl-X software in real time and NetControl-X will generate an alarm message and/or send an e-
mail to the pre-assigned accounts; 2) VP-II X also can output a digital signal through its AUX port by
modifying its firmware upon request; and 3) by sending a pre-defined Wiegand Site Code to the access
control system, please refer to Chapter 3 5.1.3 “Wiegand Output Options” for details on setting Wiegand
options. Please contact a sales representative or technical specialist for this function.
4.7 Installer Verification
To verify the Installer, (1) Press ENT key twice, (2) Enter an Installer PIN, and (3) Place a hand. When
the ENT key is entered twice, a message indicating Installer verification appears above the PIN input
screen as shown below.
Note: There is no Wiegand output or door open signal sent when an
Installer verifies.
5. Modifying User Information
5.1 Edit User
User information of enrolled Users can be modified using this function. Go to the menu as follows to edit
a User.
When the following window appears, enter a PIN or present a card of the User for VP-II X to retrieve the
User data to edit. To perform this function, the master unit must be in operation in order to update the
modified User information to all the units in the network.
This function is not applicable for smart card Users. Smart card Users must be deleted and re-enrolled.
Manager Menu > 1. User Management > 3. Edit User