background image

Dimensions

48” Gas Ranges

47"

 

7/8 

23"

2"

2" 

3

/16

 

2"

33

"

47"

 

7/8 

2"

 

1 /

8

 

25

"

2"

2"

Gas

1" 

3/8 

47"

 

7/8 

Electricity

5"

5"

 

9/16 

35

7 /

mi

37

5 /

16 

ma

1" 

1/2 

5"

1" 

11/32

 

2"

 

6 /

3/8

 

26"

 

7/8 

2" 

3/8

 

3 /

8

23"

2" 

3/16

 

2"

 

1 /

8

 

1" 

11/32

 

35

15

/32

 

m

in

 -

 3

6"

 

7 /

m

ax

 

 2

6 /

m

in

 

 4

1 /

ma

1"

 

3 /

8

1"

 

3 /

8

2" 

27/64

1"

 

3 /

8

Содержание RN483GXSS

Страница 1: ...INSTALLATION MANUAL FOR 48 GAS RANGES 461308472...

Страница 2: ...USA 28 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any e...

Страница 3: ...tare of California to cause cancer and birth defects or other reproductive harm California law requires this warning to be given to customers in the State of California An air curtain or other overhea...

Страница 4: ...uit no other receptacles switches or loads in the circuit Connected to a standard breaker of appropriate size GFI breaker of the same size NOT recommended Rated for Class A 5 mA 1 mA trip current as p...

Страница 5: ...erify your appliance has been properly grounded in accordance with local codes or in absence of codes with the National Electrical Code NEC ANSI NFPA 70 la test edition WARNING WARNING DANGER TIPPING...

Страница 6: ...ensions 48 Gas Ranges Note Unit shown with island trim Note All gas ranges are equipped with spacer on the back 25 64 to prevent over heating of the wall 47 7 8 23 2 2 3 16 33 35 7 8 min 37 5 16 max 1...

Страница 7: ...ges 2 2 33 47 7 8 2 1 8 25 2 2 Gas 1 3 8 47 7 8 Electricity 5 5 9 16 35 7 8 min 37 5 16 max 1 1 2 5 1 11 32 2 6 8 3 8 26 7 8 2 3 8 3 8 23 2 3 16 2 1 8 1 11 32 35 15 32 min 36 7 8 max 2 6 8 min 4 1 4 m...

Страница 8: ...urner Ext ring Int ring 137 2 80 5275 18000 82 2 50 5275 18000 65 1377 4700 Power burner with simmer Ext ring Int ring 137 2 80 5275 18000 82 2 50 5275 18000 60 27 1377 4700 Total gas power 85600 Oven...

Страница 9: ...immer Ext ring Int ring 137 2 80 5275 18000 82 2 50 5275 18000 60 27 1377 4700 Total gas power 46500 Oven 48 Inches left cavity 180 4103 14000 108 4103 14000 52 879 3000 Grill 48 Inches left cavity 13...

Страница 10: ...inet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wall cabinets above the range must be a minimum of 48 121 9...

Страница 11: ...d installa tion instructions for additional information These dimensions provide for safe and efficient operation of the hood Important This range comes standard with 4 backguard There must be a minim...

Страница 12: ...t of an emergency Any opeing behind the range shall be sealed In Massachusetts A T handle type manual valve must be installed in the gas supply line to the appliance IMPORTANT Any conversion required...

Страница 13: ...ressure regulator 3 Screw the assembled pressure regu lator on the range like shown on picture below Pay attention to the vertical aligne ment of the same pressure regulator Gas Requirements 4 Re inst...

Страница 14: ...ible connector or at least1 2 1 3 cm ID NPT with suitable strainreliefs in compliance with ANSI Z21 41and Z21 69 G area for gas connection E area for electric connection In Canada CAN 1 6 10 88 metal...

Страница 15: ...rinted on the body Consult the table on Specifications Technical data paragraph for matching nozzles to burners Save the nozzles removed from the range for future use STEP1 PRESSURE REGULATOR The pres...

Страница 16: ...n the body Consult the table on Specifications Technical data paragraph for matching nozzles to burners STEP 3 MAIN OVEN BURNER To replace the nozzles of the main oven burner start by removing the bot...

Страница 17: ...range or by a Tecno autho rized parts warehouse Each nozzle has a number indicating its flow diameter prin ted on the body Consult the table on Specifications Technical data para graph for matching n...

Страница 18: ...ceed to setting the minimum for each burner Gas Requirements STEP 7 MINIMUM FLAME ADJUSTMENT WARNING These adjustments should be made only for use of the appliance with natural gas For use with liquid...

Страница 19: ...be installed with the unit Refer to An ti tip Device Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be wa shed thorough...

Страница 20: ...must be done by your dealer a qualified licensed plumber or certified gas installer Door Removal 1 Open the door completely Place the pins supplied with unit in pin hole For personal safety ONLY use p...

Страница 21: ...installing the legs position the appliance near its final location as the legs are not suitable for moving the appliance over long distances After unpacking the range raise it enough to insert the le...

Страница 22: ...h the installa tion instructions in this document Device must be engaged properly to pre vent product from tipping over Anti tip Device Installation Measure from floor to the anti tip bar located in a...

Страница 23: ...ays check for gas leaks with soapy water solution DO NOT USE AN OPEN FLAMETO CHECK FOR GAS LEAKS Connect gas and electrical Before placing appliance in operation always check for gas leaks This must b...

Страница 24: ...teel Scratches arealmost impossible to remove Performance Checklist A qualified installer should carry out the following checks Check top burner ignition Push and turn the knob Full on position The lo...

Страница 25: ...00 450 F Oven temperatures Broil Broil RIGHT CAVITY Gas oven switch knob range 48 OFF Closed position from MIN to MAX Oven temperatures Electric griddle knob range 48 OFF Closed position from 1 to 7 p...

Страница 26: ...Performance Checklist OFF Cooking zone Off not activated A Accelerated heat up Turbo Boost Bridge from 1 9 Induction power levels Induction special functions Melting Warming Simmering Induction zone k...

Страница 27: ...write to CUSTOMERCARE TECNOSPA IT Record the information indicated below You will need it if service is ever required The model and serial number can be found by looking in the last page of this book...

Страница 28: ...and in home service to repair or replace the defective part This warranty is extended to the original purchaser and any succeeding owner with proper documentation of ownership for products purchased f...

Страница 29: ...acts of God 16 Expenses for travel and transportation to locations more than 30 miles from an authorized TECNOGAS SUPERIORE retailer 17 Products with original serial numbers that have been removed The...

Страница 30: ...30 INSTALLATION LABEL CONVERSION LABEL Labels...

Страница 31: ...31...

Страница 32: ...tecnogassuperiore us 461308472...

Отзывы: