A GFI shall be used if required by NFPA-70 (National Electric Code), fede-
ral/state/local laws, or local ordinances.
•The required use of a GFI is normally related to the location of a receptacle with
respect to any significant sources of water or moisture.
•TECNOGAS SUPERIORE will NOT warranty any problems resulting from GFI out-
lets which are not installed properly or do not meet the requirements below.
If the use of a GFI is required, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommen-
ded)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size
NOT recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor
situations)
•Protected from moisture (water, steam, high humidity) as much as reasonably possible
To prevent possible damage to
cabinets and cabinet finishes, use only
materials and finishes that will not
discolor or delaminate and will
withstand temperatures up to 194°F
(90°C). Heat resistant adhesive must be
used if the product is to be installed in
laminated cabinetry.
Check with your builder or cabinet
supplier to make sure that the
materials meet these requirements.
WARNING
Warnings & Important Safety Instructions