Clearance Dimensions
(Wood/Composite Overlay)
The bottom of a standard hood should be 30 ‘‘ (76.2 cm) min to 36 ‘‘ (91.4 cm) max
to above the countertop. This would typically result in the bottom of the hood being
66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the range hood installa-
tion instructions for additional information.
These dimensions provide for safe and efficient operation of the hood.
Important:
This range comes standard with 4’’ backguard. There must be a minimum
of 6” (15.2 cm) clearance from rear of range to a
combustible
wall.Clearances from
non-combustible materials are not part of the ANSI Z21.1 scope and are not certified
by CSA. Clearances to non-combustible materials must be approved by the authority
having jurisdiction.