9. INSTALLATION

•  BEFORE INSTALLING

Whilst the installation of this heater is straightforward, please ensure you read the following carefully as 

the manufacturer will not be liable for any damage or problems arising from incorrect installation.

Unwrap your heater and clear the packaging away. The packaging has been specifically chosen to allow 

you to recycle it. If on unpacking, you discover any damage whatsoever, please get in touch with your sup

-

plier within 24 hours and prior to installation.

For assembly and installation, please follow the instructions as set out in this booklet. For safety reasons, 

this heater should never be installed in close proximity to a bath or shower i.e. that you could touch the 

controls whilst in the bath or shower. The radiator should not be placed below a socket. If the cable has 

been damaged, it can only be replaced by the manufacturer, through its aftersales team, or by a qualified 

person. This ensures the user will not be in any danger. At the end of the manual, you will find a Guarantee, 

please check that this has been completed correctly, dated and stamped

Very important:

 

- Read installation manual prior to installation of this unit!

 

- Read user manual before putting this unit in operation!

 

- Observe the warnings in the manuals!

 

- The installation room must fulfil the ventilation requirements!

 

- Installation by an authorised person only!

•  CONNECTING ELECTRICITY SUPPLY

 

- If the Thermal Emitter that you have acquired does not have a plug on the supply cord, installati 

 

  on shouldbe carried out by a qualified electrician.

 

- Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring  

 

  rules of thecountry where it is to be installed.

 

- Before connecting, check the supply is switched off.

 

- Before connecting the appliance to the fixed wiring check that the voltage of supply is inside the  

 

  ratedvalues indicated in the marking plate 220 - 240V.

 

- The appliance must be connected to the fused system of fixed wiring.

 

- Any problem arising from not following the instructions above will invalidate your guarantee

 

- When wiring up, please follow the colours of wires.

•  HANGING THE HEATER

The radiator comes complete with an installation kit, comprising the following:

 

- Screws

 

- Brackets

Cardboard guide, (remove from the top of the box the radiator comes in). Please follow the illustrated 

steps below to hang and install your radiator:

1.  

Take the radiator out of its packaging and choose where to hang it. Please notethe minimum 

 

distances  required around the heater.

2. 

Remove the cardboard guide from the lid of the box and place it at the rightheight, as shown 

 

in diagram 4 below. We suggest you use a level to ensure theradiator is hung square. Using the    

 

holes as your guide, mark where the bracketsneed to go.

3. 

Drill and plug the holes.

4. 

Screw the brackets to hold the radiator into place, using the screws and washersprovided.

5. 

Place the unit so that the brackets [15] fit into the slot that has the upper profile ofthe radiator.

6. 

Approximate the radiator to the holders of the wall brackets and screw fixation.

7.   

Use a hole drill for holes with appropriate stoppers for the type of wall.

Содержание PH SlimLine

Страница 1: ...y www technotherm de 1 Model PH Slimline Instruction Manual PH SlimLine THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Id Nr 900 370 401 Edition 01 18 ...

Страница 2: ...he aluminium elements expand and contract Please note there is no danger to the user Children under 3 years old should be kept out of the equipment unless they are constantly supervised Children under 8 must only turn on off the device provided in normal position and only if they have received instruction concerning use of the equipment in a safe way and understand the risks All children under 8 y...

Страница 3: ...rst move the square cursor on the clock mode then press the key or to start the adjust ment Each time a value blinks you can adjust it with the and keys Once the value is chosen confirm it with the OK key The thermostat will move automatically to the next value List order of the time and date adjustments 1 Time and day Adjustment of the hours Adjustment of the minutes Adjustment of the day 1 Monda...

Страница 4: ... the Comfort and Reduced temperature settings You can easily override the current program temperature by changing the value with or The current settingntemperature will blink The small hand logo will be displayed when the override function is active The original temperature settings will eturn when the timer reaches the next change in the programme If hand logo blinks then ITCS is active See the u...

Страница 5: ...Shop P9 Weekend Secondary house The bars indicate the hours with comfort temperature and the rest of the day the spaces represent the eco reduced temperature mode See the appendix section to view a complete description of the Built in program Use the navigation key right to view the program of alternative days of the week Press the OK key to confirm your choice and return to the main screen in AUT...

Страница 6: ...able in all modes FUNCTION WINDOWS OPEN This function will stop the radiator automatically when it detects a window open if the radiator is running When this feature is enabled the icon appears at the top left of the screen If the system detects a fall of approximately 3 C it stops the heating for a period of 1 hour The icon will blink and the temperature will be measured by the radiator Pressing ...

Страница 7: ...perature Control System The Intelligent Temperature Control System will activate your installation in advance 2 hours maximum to assure the desired temperature at the hour programmed following your weekly pro gram This automatic control system works in the following way When you start your thermostat for the first time it will measure the time taken by your installation to reach the set temperatur...

Страница 8: ... 6 3 2004 EN 61000 4 2 2001 Low voltage 2006 95 EC EMC 2004 108 EC 8 TROUBLESHOOTING SOLUTION My Thermostat doesn t work Power supply Check the power supply My Thermostat show an Error message Err blink on the display Error on sensor Note For safety if there is a problem on the regulation sensor the regulation will be replaced by a rate of 5 functioning The logo and the text Err blinks Error detec...

Страница 9: ...rmal Emitter that you have acquired does not have a plug on the supply cord installati on shouldbe carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of thecountry where it is to be installed Before connecting check the supply is switched off Before connecting the appliance to the fixed wiring check that the v...

Страница 10: ...e a plug on the supply cord installation should be carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of the country where it is to be installed Before connecting check the supply is switched off Before connecting the appliance to the fixed wiring check that the voltage of supply is inside the rated values ind...

Страница 11: ...y problem occurring from such defects Allproblems arising from installing and undersized heater not enough heat improper installation etc are notcovered by this guarantee This heater is for domestic light commercial use only installation in any other environment voids thisguarantee Technotherm reserves the right to decide whether to repair or replace any defective part or to replace the entire hea...

Страница 12: ... 0 5 1 0 1 2 kW electronic heat charge control with room and or outdoor temperature feedback NO Auxiliary electrici ty consumption fan assisted heat output NO At nominal heat output elmax 0 9 1 5 2 0 kW Type of heat output room temperature control select one At minimum heat output elmin 1 2 1 2 1 2 kW single stage heat output and no room temperature control No 1 2 1 2 1 2 Two or more manual stages...