4           

_ ._

: Calibration of the internal probe

 

The  calibration  must  be  done  after  1  day  working  with  the  same  setting  temperature  in

 

accordance with the following description:

 

Put a thermometer in the room at 1.5M distance from the floor (like the thermostat) and check   

 

the real temperature in the room after 1 hour.

 

When you enter on the calibration parameter the actual value is displayed.

 

To enter the value shown on the thermometer, use the (-) or (+) keys to enter the real value. Then, 

 

press (Ok) to confirm. The logo        should be displayed, to inform that a calibration is now made

  

and saved in the  memory. If you need to erase a calibration already made press on the 

 

navigation key left (      ). Then the logo must disappear.

 

* Pay attention: Only the heating element managed by the thermostat must be used during the   

 

complete step of the calibration.

5           

AF

: Anti Freeze temperature:

 

This Anti-freeze temperature used in Holiday mode.

 

Adjustable 0.5 to 10.0°C with default value 5.0°C.

6           

ITCS

: Intelligent Temperature Control System

 

The Intelligent Temperature Control System will activate your installation in advance (2 hours

 

maximum) to assure the desired temperature at the hour programmed following your weekly pro 

 

gram. This automatic control system works in the following way:

 

When you start your thermostat for the first time, it will measure the time taken by your 

 

installation to reach the set temperature. The thermostat will re-measure this time at each pro   

             gram change to compensate external temperature change & influence. You can now program

  

your thermostat without the need to adjust the temperature in advance because your 

 

thermosat does it automatically for you.

7           

WIN

:  Automatic detection of open windows.

 

This feature allows detect automatically if you open a window.

 

No: deactivation of the function.

 

Yes: Activate the function

8         

Clr

: Factory setting

 

Press and maintain (Ok) key during 10s to reset Set points temperatures and user parameters in

 

this menu to factory default settings. User programs will also be resetted.

 

* Pay attention:

 

Ensure that you have all necessary elements to re-setup your installation before to use this 

 

function.

9         Software version

 

_._

10         

End

: Exit the parameter’s menu

 

Press (OK) key to exit installation parameter menu and return to normal operation.

Содержание PH SlimLine

Страница 1: ...y www technotherm de 1 Model PH Slimline Instruction Manual PH SlimLine THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Id Nr 900 370 401 Edition 01 18 ...

Страница 2: ...he aluminium elements expand and contract Please note there is no danger to the user Children under 3 years old should be kept out of the equipment unless they are constantly supervised Children under 8 must only turn on off the device provided in normal position and only if they have received instruction concerning use of the equipment in a safe way and understand the risks All children under 8 y...

Страница 3: ...rst move the square cursor on the clock mode then press the key or to start the adjust ment Each time a value blinks you can adjust it with the and keys Once the value is chosen confirm it with the OK key The thermostat will move automatically to the next value List order of the time and date adjustments 1 Time and day Adjustment of the hours Adjustment of the minutes Adjustment of the day 1 Monda...

Страница 4: ... the Comfort and Reduced temperature settings You can easily override the current program temperature by changing the value with or The current settingntemperature will blink The small hand logo will be displayed when the override function is active The original temperature settings will eturn when the timer reaches the next change in the programme If hand logo blinks then ITCS is active See the u...

Страница 5: ...Shop P9 Weekend Secondary house The bars indicate the hours with comfort temperature and the rest of the day the spaces represent the eco reduced temperature mode See the appendix section to view a complete description of the Built in program Use the navigation key right to view the program of alternative days of the week Press the OK key to confirm your choice and return to the main screen in AUT...

Страница 6: ...able in all modes FUNCTION WINDOWS OPEN This function will stop the radiator automatically when it detects a window open if the radiator is running When this feature is enabled the icon appears at the top left of the screen If the system detects a fall of approximately 3 C it stops the heating for a period of 1 hour The icon will blink and the temperature will be measured by the radiator Pressing ...

Страница 7: ...perature Control System The Intelligent Temperature Control System will activate your installation in advance 2 hours maximum to assure the desired temperature at the hour programmed following your weekly pro gram This automatic control system works in the following way When you start your thermostat for the first time it will measure the time taken by your installation to reach the set temperatur...

Страница 8: ... 6 3 2004 EN 61000 4 2 2001 Low voltage 2006 95 EC EMC 2004 108 EC 8 TROUBLESHOOTING SOLUTION My Thermostat doesn t work Power supply Check the power supply My Thermostat show an Error message Err blink on the display Error on sensor Note For safety if there is a problem on the regulation sensor the regulation will be replaced by a rate of 5 functioning The logo and the text Err blinks Error detec...

Страница 9: ...rmal Emitter that you have acquired does not have a plug on the supply cord installati on shouldbe carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of thecountry where it is to be installed Before connecting check the supply is switched off Before connecting the appliance to the fixed wiring check that the v...

Страница 10: ...e a plug on the supply cord installation should be carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of the country where it is to be installed Before connecting check the supply is switched off Before connecting the appliance to the fixed wiring check that the voltage of supply is inside the rated values ind...

Страница 11: ...y problem occurring from such defects Allproblems arising from installing and undersized heater not enough heat improper installation etc are notcovered by this guarantee This heater is for domestic light commercial use only installation in any other environment voids thisguarantee Technotherm reserves the right to decide whether to repair or replace any defective part or to replace the entire hea...

Страница 12: ... 0 5 1 0 1 2 kW electronic heat charge control with room and or outdoor temperature feedback NO Auxiliary electrici ty consumption fan assisted heat output NO At nominal heat output elmax 0 9 1 5 2 0 kW Type of heat output room temperature control select one At minimum heat output elmin 1 2 1 2 1 2 kW single stage heat output and no room temperature control No 1 2 1 2 1 2 Two or more manual stages...

Отзывы: