Information requirements for electric local space heaters

Model: PH SlimLine

Item

Symbol

Value

Value

Item

Value

Heat output

Type of heat input, for electric storage local space heaters only (select one)

Nominal heat output

P

nom

0,9

1,5

2,0

kW

manual heat charge control, with integrated thermostat

NO

Minimum heat

output (indicative)

P

min

0,5

1,0

1,2

kW

manual heat charge control with room and/or outdoor temperature 

feedback

NO

Maximum continuo-

us heat output

P

max,c

0,5

1,0

1,2

kW

electronic heat charge control with room and/or outdoor

temperature feedback

NO

Auxiliary electrici-

ty consumption

fan assisted heat output

NO

At nominal heat 

output

el

max

0,9

1,5

2,0

kW

Type of heat output/room temperature control (select

one)

At minimum heat

output

el

min

1,2

1,2

1,2

kW

single stage heat output and no room temperature control

No

1,2

1,2

1,2

Two or more manual stages, no room temperature control

No

In standby mode

el

SB

1,2

1,2

1,2

kW

with mechanic thermostat room temperature control

N0

1,2

1,2

1,2

with electronic room temperature control

No

electronic room temperature control plus day timer

No

electronic room temperature control plus week timer

Yes

Other control options (multiple selections possible)

room temperature control, with presence detection

No

room temperature control, with open window detection

Yes

with distance control option

No

with adaptive start control

Yes

with working time limitation

No

with black bulb sensor

No

Contact Information:

Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1  D-09217 Burgstädt

Содержание PH SlimLine

Страница 1: ...y www technotherm de 1 Model PH Slimline Instruction Manual PH SlimLine THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Id Nr 900 370 401 Edition 01 18 ...

Страница 2: ...he aluminium elements expand and contract Please note there is no danger to the user Children under 3 years old should be kept out of the equipment unless they are constantly supervised Children under 8 must only turn on off the device provided in normal position and only if they have received instruction concerning use of the equipment in a safe way and understand the risks All children under 8 y...

Страница 3: ...rst move the square cursor on the clock mode then press the key or to start the adjust ment Each time a value blinks you can adjust it with the and keys Once the value is chosen confirm it with the OK key The thermostat will move automatically to the next value List order of the time and date adjustments 1 Time and day Adjustment of the hours Adjustment of the minutes Adjustment of the day 1 Monda...

Страница 4: ... the Comfort and Reduced temperature settings You can easily override the current program temperature by changing the value with or The current settingntemperature will blink The small hand logo will be displayed when the override function is active The original temperature settings will eturn when the timer reaches the next change in the programme If hand logo blinks then ITCS is active See the u...

Страница 5: ...Shop P9 Weekend Secondary house The bars indicate the hours with comfort temperature and the rest of the day the spaces represent the eco reduced temperature mode See the appendix section to view a complete description of the Built in program Use the navigation key right to view the program of alternative days of the week Press the OK key to confirm your choice and return to the main screen in AUT...

Страница 6: ...able in all modes FUNCTION WINDOWS OPEN This function will stop the radiator automatically when it detects a window open if the radiator is running When this feature is enabled the icon appears at the top left of the screen If the system detects a fall of approximately 3 C it stops the heating for a period of 1 hour The icon will blink and the temperature will be measured by the radiator Pressing ...

Страница 7: ...perature Control System The Intelligent Temperature Control System will activate your installation in advance 2 hours maximum to assure the desired temperature at the hour programmed following your weekly pro gram This automatic control system works in the following way When you start your thermostat for the first time it will measure the time taken by your installation to reach the set temperatur...

Страница 8: ... 6 3 2004 EN 61000 4 2 2001 Low voltage 2006 95 EC EMC 2004 108 EC 8 TROUBLESHOOTING SOLUTION My Thermostat doesn t work Power supply Check the power supply My Thermostat show an Error message Err blink on the display Error on sensor Note For safety if there is a problem on the regulation sensor the regulation will be replaced by a rate of 5 functioning The logo and the text Err blinks Error detec...

Страница 9: ...rmal Emitter that you have acquired does not have a plug on the supply cord installati on shouldbe carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of thecountry where it is to be installed Before connecting check the supply is switched off Before connecting the appliance to the fixed wiring check that the v...

Страница 10: ...e a plug on the supply cord installation should be carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of the country where it is to be installed Before connecting check the supply is switched off Before connecting the appliance to the fixed wiring check that the voltage of supply is inside the rated values ind...

Страница 11: ...y problem occurring from such defects Allproblems arising from installing and undersized heater not enough heat improper installation etc are notcovered by this guarantee This heater is for domestic light commercial use only installation in any other environment voids thisguarantee Technotherm reserves the right to decide whether to repair or replace any defective part or to replace the entire hea...

Страница 12: ... 0 5 1 0 1 2 kW electronic heat charge control with room and or outdoor temperature feedback NO Auxiliary electrici ty consumption fan assisted heat output NO At nominal heat output elmax 0 9 1 5 2 0 kW Type of heat output room temperature control select one At minimum heat output elmin 1 2 1 2 1 2 kW single stage heat output and no room temperature control No 1 2 1 2 1 2 Two or more manual stages...

Отзывы: