5
During the fitting of the shelves to the shelf supporting arms, the operator must never stand or walk beneath the suspended
load, but must take care to stand to the sides of the two brackets, and never in between them.
3. Position part “A” on the bracket bar, from top to bottom (see fig. 2), fitting the 2 coupling teeth into loops “j” and “k”
designed for this purpose. At this point, part “A” is only fixed to the bracket (see fig. 3).
4. In order to fix part “A” to the bracket, use the 2 black fastening knobs, screwing them onto the plate nuts previously
positioned behind the wall bars (see fig. 4).
5. Fit part “B” downwards into part “A” (see fig. 5 / 10).Perform the levelling of the hoist using the 4 adjusting knobs
positioned at the ends of part “A”, in such a way that all 4 press slightly against the wall. Check the stability of the system
before proceeding with hoisting operations. Before starting the machine, ensure that it is perfectly stable and secured in
place.
6. Power the machine using the 220V socket.
7.
Position the bar (part “C”) above the condensation unit (see fig. 6), and secure the machine to the bar using the 2 straps
provided (see the instructions attached regarding the tightening of the straps). WARNING! The straps must be passed
inside the machine’s feet in order to prevent them from sliding outwards.
8.
To perform an initial hoisting test, use the control panel. To lift the load, press the “up” button on the control panel, and
keep it pressed; to lower the load, press, and keep pressed, the “down” button; the hoist will come to a halt should such
buttons be released, or when the load reaches the maximum height. Raise the external unit a few centimetres. Then
check that the machine is in perfect equilibrium; should the machine be in a sloping position, slide the eyehook along
the loop of part “C” until the machine is perfectly flat. Ensure that during hoisting, the metal cable winds around the
entire width of the drum. WARNING! Is is strictly forbidden to stand under suspended loads.
9. Lift the machine up until the base of the external unit exceeds, or is at least level with, the height of wall plate (see fig. 7)
10. Return the bracket’s shelves to a horizontal position, and lower the machine until it rests on the bracket (see fig. 8);
then secure the condensation unit in position by means of the vibration dampers, using the screws provided For the
TSMC series brackets, secure the shelves to the shelf supporting arms before lowering the machine. WARNING! Before
detaching the hoist from the external unit, ensure that the unit is correctly secured to the bracket by means of the
screws provided.
11. To disassemble the hoister, perform the same operations in reverse.