The next step to face is the field <
NMEA PROTOCOL
>. Enter one of the values
below at will. Please note that the app / software you are using to read out your
NMEA network data, supports the appropriate protocol.
Code 11 – NMEA2000 native
Code 22 – Se NMEA0183
Code 33 – NMEA0183
You can save and apply your changes by clicking on „Save“ button. The
Replicator
performs a restart and is ready for use immediately afterwards.
If you made some mistakes during setup, nothing serious will occur. You will
observe a fault either by receiving wrong coded data on your client, or the
Replicator
runs into a so called on-call standby loop.
You may push the SETUP pin on the frontside of your
Replicator
at any time and
change the values at will.
In the event of 5 minutes without any changes during setup, the
Replicator
runs its
internal Timeout, resets all settings to last known good configuration and closes
the setup wizard to prevent intrusion of unauthorized access.
Configurations field <
AP SSID
> and <
Wifi Password
> are, as a matter of course,
without significance and could be left blank when operating in Server/ Client mode
( figure 2 )
Configuration field <
NMEA PROTOCOL
> and <
OPERATION MODE
> must be
filled in any case.
A brief overview of what mentioned above:
Tab. 1 OPERATION MODE
Code
MODE
10
Access Point /
Replicator
operate as a standalone Access Point
11
Staion Mode /
Replicator
can be connected to existing WiFi router
Tab 2. NMEA PROTOCOL
Code
NMEA Data sent to the clients
11
NMEA2000 native**
22
SeaSmart** + NMEA 0183***
33
NMEA 0183***