Technosoft 2019
29
iMOTIONCUBE Technical Reference
3.5.8
Feedback connections
3.5.8.1
Single ended Incremental Encoder #1 Connection
Figure 3.20.
Single ended incremental encoder #1 connection
Remark:
In case J7 (Earth) is not present, connect the Shield (if present) to GND instead.
CAUTION!
DO NOT CONNECT UNTERMINATED WIRES. THEY MIGHT PICK UP
UNWANTED NOISE AND GIVE FALSE ENCODER READINGS.
3.5.8.2
Differential Incremental Encoder #1 Connection
Figure 3.21.
Differential incremental encoder #1 connection
Remarks:
1. For encoder#1 differential connection, external
120Ω (0.25W) terminators are required for long encoder cables,
or noisy environments.
2. The length of the cables must be up to 30m, reducing the exposure to voltage surges in industrial environment
3.
In case J7 (Earth) is not present, connect the Shield (if present) to GND instead.
Содержание iMOTIONCUBE BX-CAN
Страница 19: ... Technosoft 2019 19 iMOTIONCUBE Technical Reference 3 4 3 Pinouts for iMOTIONCUBE CAN STO ...
Страница 20: ... Technosoft 2019 20 iMOTIONCUBE Technical Reference 3 4 4 Pinouts for iMOTIONCUBE CAT STO ...