Technosoft 2019
30
iMOTIONCUBE Technical Reference
3.5.8.3
Single ended Incremental Encoder #2 TTL Connection
Figure 3.22.
Single-ended incremental encoder #2 connection
Warning: The encoder #2 inputs are connected directly to the DSP inputs and support only 3.3V. Do not connect directly
to +5V signals.
3.5.8.4
Differential Incremental Encoder #2 TTL Connection
Figure 3.23.
Differential incremental encoder #2 connection
Warning: The encoder #2 inputs are connected directly to the DSP inputs and support only 3.3V. Do not connect directly
to +5V signals.
Remarks:
-The length of the cables must be up to 30m, reducing the exposure to voltage surges in industrial environment.
3.5.8.5
Differential BiSS/SSI Feedback#2 Connection
Figure 3.24.
Differential BiSS/SSI Feedback#2 Connection