Technologies Paving Innovation Mini Line G198 Скачать руководство пользователя страница 8

 

Mini-Line G198 operating manual

 

Page 7 

The Mini-Line® Grade Control System should only be used to what it is constructed to, and most 

examples  of incorrect use are self-explanatory and therefore not described. However, certain key 

examples of misuse or inappropriate behavior are outlined below, and should be avoided.  

 

Examples of incorrect use of the system before the paving job 

Do not remove any of the labels on the G198, as they are required for product identification, e.g. in 

relation to repair and disposal.  

Do not open the aluminum house of the G198, as this will expose the electronics and can damage 

the products. The G198 must not be rebuilt or refurbished, as TF-Technologies will no longer be 

able to vouch for the quality, and rebuilding units may cause serious personal injury or material 

damage.  

The Mini-Line® cables must not be disconnected from their connectors or in any way disassembled.  

 

Examples of incorrect use of the system during the paving job 

Do not use unauthorized cables or unauthorized spare parts, as this can damage the G198 and lead 

to unpredictable control of the asphalt paver, which may result in serious personal injury or material 

damage. 

It is not recommended to connect the G198 on a paver, when power is already applied, as the 

metal jacket on the cable under unfortunate circumstances may lead to short circuiting the asphalt 

paver, if the metal jacket hits the two power supply pins at the same time.  

It is not recommended to adjust the screed manually on the built-in panel on the asphalt paver, 

while G198 is in auto mode or by use with HS301 where this is in auto mode, as the system will 

seek to counter the adjustment. Switch the G198/HS301 to manual mode instead, if adjustments 

on the built-in panel are required. 

It is not recommended to mount the G198 on an asphalt paver on the move or in operation, as this 

may remove focus from the surrounding traffic, which may result in serious personal injuries. 

 

It is not recommended to mount G198 on an asphalt paver on the move or in operation 

 

It can remove focus from the surrounding traffic, which may result in serious personal 
injuries  

 

It can remove focus from the moving parts of the machine, which may result in serious 
personal injuries 

 

Warnings and Dangerous Situations  
The Mini-Line® Grade Control System must not be used 

 

If the Mini-Line® Grade Control System is obviously damaged.  

 

If the Mini-Line® Grade Control System has been rebuilt.  

 

If the G198 is connected to asphalt pavers that use other types of input than the output the 
G198 is able to deliver.  

 

The Mini-Line® Grade Control System can be damaged 
If welding is performed on the asphalt paver or Support Arm, as large currents may travel through 

the construction and damage the electrical equipment.  

 

The following precautions should be taken before welding  

 

Remove all electrical equipment wherever possible  

 

Disconnect the negative pole on the battery of the asphalt paver, or mount voltage 
protection on the battery  

 

Place the negative electrode close to the welding point 

 

Remove paint before welding 

 

Содержание Mini Line G198

Страница 1: ...Mini Line G198 operating manual Mini Line G198 Mechanical Grade Control User Manual V G704301 Please read carefully before installation...

Страница 2: ...8 2633 Email sales tf technologies com www tf technologies com Product verification Verify for damages to equipment due to transportation In case of any damage or equipment malfunctioning contact supp...

Страница 3: ...try 2 Microprocessor unit 3 Power driver circuit Any linear displacement is accurately and quickly transformed into digital signal and after being analyzed and compared with the reference point inform...

Страница 4: ...fulfilled and have excellent low temperature characteristics The coiled cable is yellow in colour and delivers in standard length of 4 0 m when fully uncoiled The standard coiled cable consists of 2...

Страница 5: ...isher operation manual for further information on machine power control box Note Depending on user s ability installation of the mechanical sensor parts G198 Grade Control and cable connections may ta...

Страница 6: ...red Asphalt Paver Requirements A pre condition for the safe use of Mini Line Grade Control System in accordance with applicable safety regulations is that the system is only used on asphalt pavers tha...

Страница 7: ...uations and be able to avoid them Be aware of the specifications of the G198 to ensure that they are working properly See Technical Specifications data sheets Responsibility of the Operator When plann...

Страница 8: ...same time It is not recommended to adjust the screed manually on the built in panel on the asphalt paver while G198 is in auto mode or by use with HS301 where this is in auto mode as the system will...

Страница 9: ...ommence repair Precautions Inspect cables regularly for evidence of wear or deterioration Inspect the receptacles and cable connectors for damages dirt or water Caution Deposits of dirt grease and asp...

Страница 10: ...ack Mini Line G 198 PUR S 4x0 75 2x0 25mm2 CA06COM E18S 1S CA3106E14S 6S B Connector Plug CA3102E14S 6P B CA3106E14S 6S B CA06COM E18S 1S A 8 30VDC 8 30VDC Ground B Ground Ground 8 30VDC C Pulse up Pu...

Страница 11: ...ble to the failure of the equipment TF Technologies liability being specifically limited to repair as stated hereinabove This warranty is automatically initiated except where modified by contractual o...

Отзывы: