background image

 

 

 

 

 

 

Note:

 

When measuring under the measurement range, the display shows 

“0.0%” or “Lo”. 

For measurements above the measurement range, the

 

display shows 

“Hi”. 

  Remove the protective cap (1) . 

  Press both measuring pins (2) against the surface  at the same time. After 1 -2 seconds you 

can read the percentage  value.  

Содержание WZ 1300

Страница 1: ... on the device to other users Scope of delivery Immediately after unpacking please check the package contents for completeness and if all parts and the product are in good condition 1 Moisture Meter 1 Instructions for use Technical Data Operating voltage 9V 15 mA Battery type 6F22 6LR61 9 V block battery Operating temperature 0 C to 40 C Protection class IP 20 Resolution 0 1 Air humidity up to a m...

Страница 2: ...ning the safe use of the appliance and have understood the resulting risks Children should never play with the device Cleaning and user maintenance must not be performed by children without supervision Intended use This device is suitable for measuring wood and building moisture for example in firewood paper cardboard mortar concrete or plaster The device is only intended for use in private househ...

Страница 3: ...or rough surfaces if necessary For delicate surfaces complete the measurement on a section that is not in the visible Area Note The measuring pins are sharp and may dent or damage the surface Rub the damp residue on the surface before taking the measurement Measure several places and take an average value Be aware that salts can increase the conductivity of water This can lead to incorrect reading...

Страница 4: ...range the display shows 0 0 or Lo For measurements above the measurement range the display shows Hi Remove the protective cap 1 Press both measuring pins 2 against the surface at the same time After 1 2 seconds you can read the percentage value ...

Страница 5: ...splay You can change the temperature display between C and F by holding down the button 4 for approximately 5 seconds Troubleshooting Error Possible causes and solutions The measurement is obviously too high or low Check whether the device is set to the correct material Check if the measuring pins 2 are correctly pressed against the material Repeat the measurement process The display 7 is reading ...

Страница 6: ...harge and do not dispose of batteries in fire as the batteries may explode Ensure batteries are stored away from metal objects as contact may cause a short circuit Avoid exposing batteries to extreme temperature or humidity or direct sunlight Keep all batteries out of reach from children They are a choking hazard Use the product only for its intended purpose Consideration of duty according to the ...