background image

WZ 1300 Moisture Meter manual 

 

Please  read  the  manual  carefully  and  familiarize  yourself  with  the  functions  of  the  unit  before 

using  it.  Retain  these  instructions  for  future  reference  and  pass  them  on  together  with  the 

devic e when you pass on the device to other users.

 

 

Scope of delivery 

Immediately after unpacking  please check the package cont ents for completeness and if all 

parts and the  product are in good condition.  

1 Moisture Meter 

1 Instructions for use 

 

Technical Data 

Operating  voltage: 9V 

, 15 mA 

Battery type: 6F22/6LR61 (9 V block battery)  

Operating temperature: 0 °C to 40 °C 

Protection class: IP 20 

Resolution: 0.1%  

Air humidity: up to a maximum  of 80% (relative) 

 

Prodcut Overview   

 

 

Содержание WZ 1300

Страница 1: ... on the device to other users Scope of delivery Immediately after unpacking please check the package contents for completeness and if all parts and the product are in good condition 1 Moisture Meter 1 Instructions for use Technical Data Operating voltage 9V 15 mA Battery type 6F22 6LR61 9 V block battery Operating temperature 0 C to 40 C Protection class IP 20 Resolution 0 1 Air humidity up to a m...

Страница 2: ...ning the safe use of the appliance and have understood the resulting risks Children should never play with the device Cleaning and user maintenance must not be performed by children without supervision Intended use This device is suitable for measuring wood and building moisture for example in firewood paper cardboard mortar concrete or plaster The device is only intended for use in private househ...

Страница 3: ...or rough surfaces if necessary For delicate surfaces complete the measurement on a section that is not in the visible Area Note The measuring pins are sharp and may dent or damage the surface Rub the damp residue on the surface before taking the measurement Measure several places and take an average value Be aware that salts can increase the conductivity of water This can lead to incorrect reading...

Страница 4: ...range the display shows 0 0 or Lo For measurements above the measurement range the display shows Hi Remove the protective cap 1 Press both measuring pins 2 against the surface at the same time After 1 2 seconds you can read the percentage value ...

Страница 5: ...splay You can change the temperature display between C and F by holding down the button 4 for approximately 5 seconds Troubleshooting Error Possible causes and solutions The measurement is obviously too high or low Check whether the device is set to the correct material Check if the measuring pins 2 are correctly pressed against the material Repeat the measurement process The display 7 is reading ...

Страница 6: ...harge and do not dispose of batteries in fire as the batteries may explode Ensure batteries are stored away from metal objects as contact may cause a short circuit Avoid exposing batteries to extreme temperature or humidity or direct sunlight Keep all batteries out of reach from children They are a choking hazard Use the product only for its intended purpose Consideration of duty according to the ...

Отзывы: