6.2.3.7 CHECKING THE IP ADDRESS - DEFAULT GATEWAY - NETMASK
Command
Notes
Command
@RNETPARAM#
Displays the console’s IP address, the default
gateway and the netmask the console is current-
ly using (regardless of whether these have been
assigned in DHCP mode or have been config-
ured as static).
Table 28
6.2.3.8 READING THE WI-FI POWER
Command
Notes
Command
@RWIFIRSSI#
Shows the Wi-fi receiving power.
Table 29
The signal must be above -85dBm (e.g. -80dBm = OK).
6.2.4 CONFIGURING THE REALTIME MONITOR
6.2.4.1 SETTING PARAMETERS
Command
Notes
Command
@SRTMSOCKET ip_add port#
Sets the IP address and the UDP port where the
realtime monitor is located.
Table 30
The parameter
ip_add
indicates the IP address where the real-time monitor is located. The param
-
eter
port
indicates the number of the UDP power at which the real-time monitor is located.
6.2.4.2 SETTING THE DATA SEND PERIOD
Command
Notes
Command
@SRTMPOLLING tsend#
Sets the data send period to the realtime mon
-
itor.
Table 31
Skillmill
Technical Service Guide - Rev. 2.2
Page 44
e-mail:
Содержание Skillmill Console
Страница 1: ...Skillmill Technical Service Guide Rev 2 2 SEPTEMBER 2016...
Страница 2: ......
Страница 4: ...Blank page Skillmill Technical Service Guide Rev 2 2 Page 4 e mail support technogym com...
Страница 32: ...Skillmill Technical Service Guide Rev 2 2 Page 32 e mail support technogym com Blank page...
Страница 34: ...Blank page Skillmill Technical Service Guide Rev 2 2 Page 34 e mail support technogym com...
Страница 64: ...Blank page Skillmill Technical Service Guide Rev 2 2 Page 64 e mail support technogym com...
Страница 66: ...Blank page Skillmill Technical Service Guide Rev 2 2 Page 66 e mail support technogym com...
Страница 70: ...Blank page Skillmill Technical Service Guide Rev 2 2 Page 70 e mail support technogym com...
Страница 72: ...Blank page...
Страница 75: ......