Troubleshooting
Problem
Cause
Remedy
Problems in monitoring
heart rate with the chest
band
Other transmitters situated nearby.
Move the equipment far enough away to stop signal
interference (minimum distance between two units 80 cm).
Strong interference sources nearby.
Find the interference source (e.g. an electrical household
appliance) and move it away, or move the equipment.
Worn heart rate monitor chest band.
Change the chest band.
Chest band transmitter not making proper skin contact.
Dampen the inside of the chest band with water.
Damaged transmitter.
Change the chest band.