![Technogym ACTIVE Wellness TV RUN EXCITE Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/technogym/active-wellness-tv-run-excite/active-wellness-tv-run-excite_machine-configuration_1070158035.webp)
ACTIVE WTV: Machine configuration
1.10.1. I2C D
EVICE
T
EST
The I2C Device test checks the communication following the 32K and 256K memories. The test
can have two outcomes:
•
“Test Successful”:
Signifies that data packets were successfully transmitted and received
toward the display board.
•
“EEPROM Error”
: Signifies that the display board has communication problems with the memories.
1.10.2. CS
AFE
COM
TEST
The test checks the communication on CSafe ports. The test can have two outcomes:
•
“Test Successful”:
This means that the test was completed successfully, i.e. that serial
communications on the selected port are correct.
•
“Error COM1”:
This means that the outcome of the test was negative.
The “CSafe COM test” done on a machine which CSafe port is not plugged with the
monitor plug described at chapter 4 of the Service & Maintenance manual.
1.10.3. L
OW
K
IT
COM T
EST
The test checks the communication with the Low kit. The test can have two outcomes:
•
“Test Successful”:
This means that the test was completed successfully, i.e. that serial
communications on the selected port are correct.
•
“Error COM2”:
This means that the outcome of the test was negative.
1.10.4. TGS COM T
EST
The test checks the communication with the TGS reader. The test can have two outcomes:
•
“Test Successful”:
This means that the test was completed successfully, i.e. that serial
communications on the selected port are correct.
•
“Error COM3”:
This means that the outcome of the test was negative.
The “TGS COM test” done on machine not provided with the key reader gives a fail outcome.