![Technogym ACTIVE Wellness TV RUN EXCITE Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/technogym/active-wellness-tv-run-excite/active-wellness-tv-run-excite_machine-configuration_1070158023.webp)
ACTIVE WTV: Machine configuration
To correctly display the parameter values, you need to load them from the low kit, using
the “Read from low kit” function.
In addition to the machine usage data, this function also includes the 2 sub-functions described
below:
1.2.9.1.
Read from low kit
To read the parameter values from the low kit memory and view them on the display, press
READ
FROM LOW KIT
key.
1.2.9.2.
Write to low kit
To write the values of the currently displayed parameters to the low kit, press
WRITE TO LOW
KIT
key.
1.2.9.3. Default
Setting
To load the default parameter values, press
DEFAULT SETTING
key.
1.3. INVERTER AUTOTUNING
Whenever the AT driver is first connected to the motor, for example when one of the two
components is replaced, it is necessary to launch an autotuning function which analyses its phase
resistance.
Carry out the operation by setting parameter
C-100
(address 806) to
“1”
, following the detailed
instructions provided in paragraph 1.2.8. “Read/Write registers”.
Although the changes made to the parameters come into effect immediately, they are not
automatically stored in permanent memory; this requires a specific write operation
effected using the command C-0: at address 800 write the value “1”, following the
detailed instructions provided in paragraph 1.2.8. “Read/Write registers”.
Incorrect programming of the AT driver may cause serious damage to the machine, or
result in malfunctions potentially dangerous to the user. Therefore, only attempt to
program the inverter if you are certain of performing the procedure correctly.