1. ABOUT THIS MANUAL 

 
This product is equipped with safety features. Nevertheless, read the safety 
warnings  carefully  and  use  the  product  only  as  described  in  this  manual  to 
avoid injury or damage.  Keep this manual for future reference.  
 
 
Symbols in this manual:  
 

 
This danger symbol indicates potential injury or handling errors.  
 

  

 

This information symbol indicates supplementary  information   

 

2. SAFETY WARNINGS 

 

Not following the instructions as set forward in this manual; 
makes  void  any  warranty  claims  or  claims  for  damages  to 
property  and  injuries  to  persons  resulting  from  the  use  of 
this equipment!  

 

Ceveron

 MFU 500 must not be used with any other type of power supply as 

the one included! 

 

Check  safety  features  of  the  instrument  regularly  e.g.  for  damage  to  the 
housing, vacuum line, etc. 
Maintenance or repair must only be performed by a specialist! Do not open 
the  housing  of  the  instrument,  Opening  the  housing  or  modifications  to  or 
attempts to repair the instrument will make void any warranty claims. 

 

 

The power supply is delivered with the appropriate plug for your country. 
The voltage to be used in connection with Ceveron

®

 MFU 500 is preset 

to  12  V  DC.  The  correct  settings  for  your  country  are  preset  by 
Technoclone  as  is  the  polarity  of  the  voltage  adapter.  You  must  not 
change the settings! 

 

The respective accident prevention regulations of the Employer and the 
respective  rules  put  forward  by  the  respective  Liability  Insurance 
Association for electrical systems and equipment must be observed. 

 

In  training  facilities  the  handling  of  power  supplies  must  be  supervised 
by trained personal. 

 

Do not touch the power supply with wet hands and avoid water spillage 
of the power supply. 

 

Capacitors  in  the  instrument  may  still  be  charged  even  when  the 
instrument has been disconnected from the power supply. 

 

Never plug in the power supply immediately after it has been brought in 
from the cold. Formation of condensing water can destroy the unit. Allow 
the instrument to reach room temperature before plugging it in. 

 

The power supply output connecting cable must not be extended.  

 

The Power Supply can become hot during operation. Ensure the device 
has sufficient ventilation. Ventilation slots must not be covered! 

 

The  Power  Supply  must  not  be  plugged  in  when  the  unit  shows  visible 
sings of damage or the unit does no longer function. 

  
  

Содержание Ceveron MFU 500

Страница 1: ......

Страница 2: ...onding receiver plates for collecting the filtrates and the retained particles It allows rapid collection of filtrates and retained particles for a large number of applications It is specifically desi...

Страница 3: ...ur country The voltage to be used in connection with Ceveron MFU 500 is preset to 12 V DC The correct settings for your country are preset by Technoclone as is the polarity of the voltage adapter You...

Страница 4: ...utton Press to release the vacuum after the pump has stopped g Case Contains vacuum pump and electronic parts h Manometer pressure gauge Gives the pressure during filtration in inch Hg or kPa i Tubing...

Страница 5: ...fferent voltage it has to be changed before using it together with Ceveron MFU 500 Before changing the output voltage remove the In Plug Power Supply from the AC socket Make sure that the In Plug Powe...

Страница 6: ...e the samples into the filter plate Never use the unit without receiver plate The filtrate would be lost and the manifold contaminated Remember the orientation of the plate e g well A1 on the top left...

Страница 7: ...e whole plate has to be sealed independent off the number of filled wells Make sure the foil is tightly put on the surface of the filter plate We recommend to use a fresh foil for every filtration Aft...

Страница 8: ...lyophilized plasma do not require pre filtration 6 REPLACING O RING AND GASKET An accessory kit containing an additional O ring gasket and Allen wrench is included with each unit of Ceveron MFU 500 O...

Страница 9: ...ut receiver plate or leaking receiver plates Rinse unit with distilled water followed by pumping air through the unit If problems continue after trying the suggested solutions contact sales technoclon...

Страница 10: ...1200 mA max UPA 2000 2000 mA max Ripple approx 100 mV Dimensions LxWxH UPA 1200 approx 105 x 60 x 43 mm UPA 2000 approx 118 x 62 x 39 mm without AC plug adapter respectively 10 ORDERING INFORMATION RE...

Страница 11: ...btained when the distributor or Technoclone GmbH has received pages 2 of the warranty card Notice The information in this document is subject to change without notice and should not be construed as a...

Отзывы: