![Techno GR F3S-TGR-SB2 Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/techno-gr/f3s-tgr-sb2-series/f3s-tgr-sb2-series_user-manual_1069834009.webp)
SB series
User’s manual
17
The following table shows the standard models available in the SBx-HR
series, based on the length of bars and their operating features.
All the models in the SBx-HR series guarantee 14 mm resolution.
Models
Height
controlled
mm
Total
height
mm
Total
number
of optical
units
Response
time ms
Number
of
modules
Number of
optical units
per module
SBx-HR-150 150 286 21
15
7
3
SBx-HR-300 300 389 42
18
7
6
SBx-HR-450 450 536 63
22
7
9
SBx-HR-600 600 683 84
24
6
14
SBx-HR-750 750 830 105
27
7
15
SBx-HR-900 900 977 126
30
6
21
SBx-HR-1200 1200 1271 168
36
8
21
SBx-HR-1500 1500 1565 210
42
10
21
SBx-HR-1650 1650 1712 231
45
11
21
SB series
User’s manual
18
7 ALIGNMENT
PROCEDURE
After completing correct mechanical assembly and connections, as
described in the previous sections, the barrier should be aligned as
follows:
x
Disconnect the barrier’s power supply.
x
Open the
test/restart
contact.
x
Restore the barrier’s power supply.
x
Adjust the direction of the barrier by moving the receiver or
transmitter. The 2 yellow leds located on the receiver will both be
lit when the barrier is aligned correctly.
x
After aligning the barrier, secure the bolts firmly.
x
Disconnect the power supply.
x
Restore the barrier’s power supply (with the
test
contact closed);
it will enter operating mode.
x
Complete all the checks described in the final controls and those
required for routine maintenance.