TECHNISONIC INDUSTRIES LIMITED
www.til.ca
TFM-30 Installation & Operating Instructions
TiL 98RE244 Rev n/c Issue 9
2-8
7.
The display will now show "RX DPL:" and the current 3-digit DPL code. If no DPL
code is required "000" should be entered. Please note that if a DPL code is to be
programmed a CTCSS tone should not be enabled.
8.
Use the keypad to enter the required octal 3-digit DPL (Digital Coded Squelch or
DCS) code. A list of all usable and unique octal 3-digit DPL/DCS codes is as follows:
017*
051 116 156 243 266*
346 431 466 612 721
023 053*
122*
162 244 271 351 432 503 624 731
025 054 125 165 245 274*
356*
445 506 627 732
026 065 131 172 246*
306 364 446*
516 631 734
031 071 132 174 251 311 365 452*
523*
632 743
032 072 134 205 252*
315 371 454*
526*
654 754
036* 073 143 212* 255* 325* 411 455* 532 662
043 074 145*
223 261 331 412 462*
546 664
047 114 152 225*
263 332*
413 464 565 703
050*
115 155 226 265 343 423 465 606 712
TABLE 2.2
Usable and unique octal 3-digit DPL/DCS
NOTE: * indicates GE Digital Coded Squelch (DCS) Code
9.
Press ENTER. "TX DPL" appears on the display. Repeat step 8.
10.
Press ENTER. "G1 DPL" appears on the display. Repeat step 8.
11.
Press ENTER. "G2 DPL" appears on the display. Repeat step 8 and press ENTER.
2.14 PC MEMORY PROGRAMMING UP/DOWNLOAD CAPABILITY
The Technisonic Data Programmer (Multi-TDP) Windows based software is supplied on a CD
with the TFM-30 transceiver or is available for download from our web site www.til.ca. This
software will allow anyone with a standard personal computer (PC) and the PIB-100
programming box to send or retrieve data from a connected TFM-30 transceiver for editing,
sorting and sharing with other Technisonic transceivers.
The Multi-TDP programmers are 32-bit Windows applications that will work under Windows
95/98, Windows NT 4.0 and Windows 2000. Documentation for each of the respective
Programmers is available from the pull down "Help" menu at the top of the programmer
display. To use the Windows based program with the TFM-30, the PIB-100 programming
interface box P/N 001108-1 includes all required cables and must be purchased from
Technisonic or other re-sellers.
The CD supplied with the transceiver also contains a DOS based download program that can
be used with the TFM-30 and no interface box. However, changes in operating systems and
PC hardware that have occurred since the release of our DOS compatible software prevent
it from working with most modern computers. Computers with 486 processors or some
early Pentium type processors of 200 MHz or less running MS-DOS seem to work the best.
Please check the “Programmer downloads” link on our website www.til.ca for further
information regarding PC programming information for users of single band transceivers like
the TFM-30.
The user instructions for the Windows based Multi-TDP software and then the DOS-based
software follow below.