Menu digital CAN network inputs DIGINW (only UVR1611) 

 
This selection is only possible for the controller UVR1611.

 

For output 14, the query

 

NETW.IP.=>DL.:

 

must be set to

 "

yes

". 

 
 
 
 

Access the menu via a long key press. 

 

Selection via a long key press at the rele-
vant digital network input. The selection is 
indicated by a star. 
 
 
 
 
 
 
 

 

 
 
 

Up to 16 digital network inputs can be displayed. 

 
 
 
 
 

 

 
 
Display example: 

 
Current value of the digital network input 1. "ND1" and "OFF" flash al-
ternately. 
 
 

 

Содержание RAS PLUS DL

Страница 1: ...www ta co at English RAS DL Room sensor with remote display Version 2 03 Operation Programming Installation Instructions...

Страница 2: ......

Страница 3: ...FFSET 12 Display of operating mode symbols SYMB 13 Menu VALUES 14 Menu sensor values SENSOR 14 Menu speed stages SPEED only UVR1611 16 Menu heat quantity counter POWER 17 Menu external sensors NETW on...

Страница 4: ...ntity counter outputs and network inputs at the RAS DL remote display Programming of the sensor permits the setting of which values and symbols are to be output to the display Moreover there is a choi...

Страница 5: ...ndby position leftmost of the slider switch RAS DL can be configured using the key and set up to display further values The following symbols are used in the menu descriptions to differentiate between...

Страница 6: ...respective controller types Menu overview UVR16x2 RSM610 CAN I O45 and UVR1611 In the menu section CONFIG gen eral sensor settings are adjusted The selection of the values and sym bols to be displaye...

Страница 7: ...d ESR31 UVR61 3 from version 8 3 UVR63 from version 1 5 In the menu section CONFIG gen eral sensor settings are adjusted The selection of the values and sym bols to be displayed takes place in the men...

Страница 8: ...en eral sensor settings are adjusted The selection of the values and sym bols to be displayed takes place in the menu section VALUES The menu option POWER heat quantity counter is only displayed with...

Страница 9: ...DE and Eng lish EN Factory setting DE To activate the language selection the RAS DL must be initialised by scrolling forward into the display level Time interval for continuing display TIME N Entry 0...

Страница 10: ...s in the DL bus network DL ADR Upon querying by the controller ESR31 UVR63 from version 1 0 ESR21 UVR61 3 and UVR63 H from version 5 0 UVR1611 from version A3 00 plus UVR16x2 RSM610 and CAN I O45 the...

Страница 11: ...d UVR63 H 6 Room temperature with offset values for adjustment and the DIP switch 51 2 K for standard mode 102 4 K for setback mode 153 6 K for standby mode for evaluating the position of the DIP swit...

Страница 12: ...ity value is indicated in these controllers as a dimensionless value without a decimal point e g 35 5 Controller display 355 The values of indices 1 and 5 would be indicated with 999 and therefore can...

Страница 13: ...ong those controllers that have no bidirectional data link e g HZR65 i e those for which the RAS DL can only be used as a remote display this menu option is still displayed but has no effect and can t...

Страница 14: ...etwork inputs DIGINW only UVR1611 Symbol allocation SYMB Menu sensor values SENSOR Access the menu via a long key press Selection via a long key press at the sensor in question The selection is indica...

Страница 15: ...controller UVR16x2 are displayed correctly only if they are defined as switching out puts Display example Output O1 is switched off If the heating controller UVR63 H s outputs O2 and O3 are used for a...

Страница 16: ...nu via a long key press Selection via a long key press on the rele vant output The selection is indicated by a star The speed of this output is displayed after all the other displays have been dis pla...

Страница 17: ...9 kWh is reached the counter resets to 0 and the MWh display is increased by 1 MW1 4 metered heat quantity in MWh 1 4 Number of the heat quantity coun ter for controllers UVR16x2 and UVR1611 in the pr...

Страница 18: ...listed above as only these controllers can display external sensors via the data link Access the menu via a long key press Selection via a long key press at the rele vant external sensor The selection...

Страница 19: ...t be set to yes Access the menu via a long key press Selection via a long key press t the relevant analogue network input The selection is in dicated by a star Up to 16 analogue network inputs can be...

Страница 20: ...4 the query NETW IP DL must be set to yes Access the menu via a long key press Selection via a long key press at the rele vant digital network input The selection is indicated by a star Up to 16 digit...

Страница 21: ...his sym bol is not allocated to a value Example The output O1 is already allocated the pump symbol By scrolling forwards with short key presses the desired burner symbol appears in the display Confirm...

Страница 22: ...ut or a Digital CAN network input UVR1611 then it is shown in each display view for as long as the output or the digital network input is set to ON If an output or a digital network input is displayed...

Страница 23: ...ss the menu via a long key press By scrolling forwards with short key presses the desired burn er symbol appears in the display A long key press causes the allocation to be cleared The symbol can then...

Страница 24: ...hen the menu language is selected DE German EN English the tool symbol flashes A long key press causes the language to be selected The INIT display appears briefly The first display value the room tem...

Страница 25: ...mbol Set value adjustment only when using the room sensor Using the rotary knob the room set temperature at the controller can be changed by 4 0K This display indi cates the size of the change Rotatio...

Страница 26: ...nce room the room sensor RAS DL can also be used merely as a remote control by using Index 5 as the meas ured value Using this method a fixed value of 20 C with offset values of the setting and the sl...

Страница 27: ...bus Any cable with a cross section of 0 75 mm can be used for the data link e g twin strand having a max length of 30 m For longer cables we recommend the use of shielded cable Technical data Dimensio...

Страница 28: ...ng and installation instructions or incorrect maintenance 4 The guarantee claim will expire if repairs or actions are carried out by persons who are not au thorised to do so or have not been so author...

Отзывы: