background image

 

Guarantee conditions 
 

Note: 

The following guarantee conditions do not in any way limit the legal right to a guarantee, rather 

expand your rights as a consumer. 
 

1.  The  company  Technische  Alternative  elektronische  Steuerungsgerätegesellschaft  m.  b.  H. 

provides a two-year guarantee from the date of purchase by the end consumer for all the de-
vices and parts which it sells. Defects must be reported immediately upon detection and within 
the guarantee period. Technical support knows the correct solution for nearly all problems. In 
this  respect,  contacting  us  immediately  will  help  to  avoid  unnecessary  expense  or  effort  in 
troubleshooting.  

 

2.  The guarantee includes the free of charge repair (but not the cost of on-site fault-finding, re-

moval, refitting and shipping) of operational and material defects which impair operation. In the 
event that a repair is not economically worthwhile according to the assessment of Technische 
Alternative, the goods will be replaced.  

 

3.  Not included is damage resulting from the effects of overvoltages or abnormal ambient condi-

tions. Likewise, no guarantee liability can be accepted if the device defect is due to: transport 
damage for  which  we  are  not  responsible,  incorrect  installation  and  assembly,  incorrect  use, 
non-observance of operating and installation instructions or incorrect maintenance.  
 

4.  The guarantee claim will expire if repairs or actions are carried out by persons who are not au-

thorised  to  do  so  or  have  not  been  so  authorised  by  us  or  if  our  devices  are  operated  with 
spare, supplementary or accessory parts which are not considered to be original parts. 

 

5.  The defective parts must be sent to our factory with an enclosed copy of the proof of purchase 

and a precise description of the defect. Processing is accelerated if an RMA number is applied 
for  via our home page 

www.ta.co.at

.

 

A prior clarification of the defect with our technical sup-

port is necessary. 

 

6.  Services provided under guarantee result neither in an extension of the guarantee period nor 

in  a  resetting  of  the  guarantee  period.  The  guarantee  period  for  fitted  parts  ends  with  the 
guarantee period of the whole device.  

 

7.  Extended or other claims, especially those for compensation for damage other than to the de-

vice itself are, insofar as a liability is not legally required, excluded. 

 

 
 
 
 
 
 
Legal notice 

These assembly and operating instructions are protected by copyright.  

Use outside the copyright requires the consent of the company Technische Alternative elektronische 
Steuerungsgerätegesellschaft  m.  b.  H..  This  applies  in  particular  to  reproductions,  translations  and 
electronic media.

 

 
 
 
 
 
 
 

elektronische Steuerungsgerätegesellschaft m. b. H.  

A-3872 Amaliendorf Langestraße 124 
Tel +43 (0)2862 53635                     Fax +43 (0)2862 53635 7 

 

E-Mail: 

[email protected]

                      --- www.ta.co.at  ---                                   © 2014 

 

Содержание FRISTAR

Страница 1: ...FRISTAR Version 2 01 EN Manual version 3 Fresh water station Operating manual en...

Страница 2: ...diagram of a cascade with four FRISTAR fresh water stations 11 Cascade switching control with UVR61 3R or UVR63 12 Control of cascade switching with UVR1611 13 Cascade switching with circulation line...

Страница 3: ...es provided in the insulated base in such a way that direct contact with the pump casing and the pipes is prevented Before switching on check whether the supply voltage matches that stated on the powe...

Страница 4: ...ater is returned to bottom layer of the buffer tank The speed control of the primary circuit pump takes place in the FRISTAR controller based on the measurements of the volume flow sensor in the hot w...

Страница 5: ...all valve Ball valve with gravity brake Ball valve Ball valve Hot water Secondary circuit Cold water Secondary circuit Volume flow sensor Primary sensor Controller Pump Power cable Plate heat exchange...

Страница 6: ...ling or cleaning as nec essary Special accessories VMS pre mixing set If the tank is operated at a temperature higher than 70 C a pre mixer that restricts the tem perature to less than 70 C must be us...

Страница 7: ...this the locking bolt of the return valve with the gravity brake is placed in a 45 position so that it is non operational Slowly fill the house system with drinking water via the secondary side ball...

Страница 8: ...8 Dimensions Housing dimensions W x H x D 366 x 573 x 160 mm 38 38 160 470 562 562 228...

Страница 9: ...with a connection for a circulation line To lead the circulation line through to the heat exchanger the isolation cap must be cut out to suitable dimensions Hydraulic circuit diagram with circulation...

Страница 10: ...Demounting of pipe elements 1 4 including pump from the heat exchanger 2 Removal of the pump and installation in the correct position 3 Remount pump connection plug 5 on the other side 4 Mounting of...

Страница 11: ...e than 40 litres per minute the overriding controller must increase the number of stations in steps of approx 8 10 l min This ensures that the sensors in the FRISTAR stations are not strained excessiv...

Страница 12: ...ting 8 Par All three max input and output thresholds are left with factory settings 75 70 C because they do not influence control 9 Par Because the flow values of the sensors are displayed as temperat...

Страница 13: ...off thresholds are identical to those of the UVR61 3 Cascade switching with circulation line Hydraulics schematic diagram Figure with fresh water stations version version Pump on the right The circul...

Страница 14: ...the run time 20 or 40 seconds set with the selector switch After the end of the run time pump start up is permitted only after a 10 minutes break Electrical circuit diagram Plug for volume flow sensor...

Страница 15: ...ller settings ON EIN The pump is switched on continuously at full speed independent of the control temperature Selection switch runtime circulation pump The selection occurs by means of a slide switch...

Страница 16: ...ry G external thread Materials corresponding to DVGW W270 Fittings Brass CW617N Heat exchanger Stainless steel 1 4401 copper soldered Pipes Copper 99 96 Seal material PTFE EPDM Klingersil C 4324 Pump...

Страница 17: ...ss characteristic curve plate heat exchanger Pressure loss characteristic pump 1 m WC 98 mbar Flow l min Pressure mbar Durchfluss m h Pressure m WC Flow m h 0 100 200 300 400 500 600 0 5 10 15 20 25 3...

Страница 18: ...H value 7 9 Electrical conductivity 10 500 S cm Free carbonic acid 20 mg l Nitrate 100 mg l Sulphate 100 mg l Saturation index SI 0 2 0 0 2 Total hardness 6 15 dH Filterable substances 30 mg l Free ch...

Страница 19: ...ctrical controls for household and similar use Part 1 General requirements EN 61000 6 3 2007 A1 2011 Electromagnetic compatibility EMC Part 6 3 Generic standards Emis sion standard for residential com...

Страница 20: ...ation instructions or incorrect maintenance 4 The guarantee claim will expire if repairs or actions are carried out by persons who are not au thorised to do so or have not been so authorised by us or...

Отзывы: