10
Interchanging connections
For optimum matching of the pipelines to the freshwater station it is possible to interchange
the connections (right/left). Doing this does not change the circulation line heat exchanger
openings or the venting of the primary circuit.
Version
Version
"Pump right" "Pump left"
Procedure:
1. Demounting of pipe elements 1 - 4 including pump from the heat exchanger
2. Removal of the pump and installation in the correct position.
3. Remount pump connection plug 5 on the other side.
4. Mounting of pipe elements 1 - 4 and the pump on the heat exchanger (see figures
above) on the other side, correct positional setup of the volume flow sensor
5. Commissioning according to the "Commissioning" chapter
Important:
The primary and secondary connections must be exchanged together!